Year 2014 - Volume 34, Number 7
|
|
Standardization of unmodified gold nanoparticle (AuNPs) for detection of Actinobacillus pleuropneumoniae in swine lungs, 34(7):621-625
|
ABSTRACT.- Brandão L.N.S., Pitchenin L.C., Maruyama F.H., Chitarra C.S., Silva G.F.R., Klein C., Nakazato L. & Dutra V. 2014. [Standardization of unmodified gold nanoparticle (AuNPs) for detection of Actinobacillus pleuropneumoniae in swine lungs.] Padronização da técnica de nanopartícula de ouro não modificada (AuNPs) para detecção de Actinobacillus pleuropneumoniae em pulmões de suínos. Pesquisa Veterinária Brasileira 34(7):621-625. Laboratório de Microbiologia e Biologia Molecular, Universidade Federal do Mato Grosso, Av. Fernando Corrêa da Costa2367, Bairro Boa Esperança, Cuiabá, MT 78060-900, Brazil. E-mail: valdutra@ufmt.br
Based on diagnostic tests for the detection of nucleic acids without amplification through the use of gold nanoparticles (AuNPs) have been described for various diseases. This study aimed to develop a technique of unmodified AuNPs to detect Actinobacillus pleuropneumoniae (App). We used 70 lung samples from pigs, 17 with and 53 without characteristic lesions of pneumonia, to detect App. The primer used was based on ApxIV gene. The AuNPs test had a sensitivity of 93.8% and specificity of 84.6% when compared with PCR detection. The results showed good agreement between AuNPs and PCR testing, and the technique can be used as an alternative to conventional tests, since it is quick and easy, and does not require implementation infrastructure and skilled labor. |
|
|
|
|
|
|