Year 2012 - Volume 32, Number 3


Title
Fluorescent Multiplex PCR for detection of bacteria in semen bovine, 32(3):211-216
Authors

Abstract
ABSTRACT.- Dias F.E.F., Nunes C.M., Cavalcante T.V., Santos H.D. Minharro S. & Garcia J.F. 2012. [Fluorescent Multiplex PCR for detection of bacteria in semen bovine.] PCR Multiplex fluorescente para detecção de bactérias em sêmen bovino. Pesquisa Veterinária Brasileira 32(3):211-216. Escola de Medicina Veterinária e Zootecnia, Universidade Federal do Tocantins, BR 153 Km 132, Zona Rural, Araguaína, TO 77804-970, Brazil. E-mail: eldadias@uft.edu.br

This study aimed to evaluate the threshold of detection of fluorescent multiplex PCR coupled with capillary electrophoresis for detection of infectious agents in semen samples from experimentally infected with decreasing concentrations of the bacteria Brucella abortus, Leptospira interrogans serovar pomona, Campylobacter fetus and Haemophilus somnus. Samples of bovine semen were experimentally infected with decreasing concentrations of bacteria obtained from serial dilutions in the base 10 so as to obtain samples containing a long time until 10-7 bacteria/mL from the initial concentration of Lepstospira pomona, Brucella abortus, Haemophilus somnus and Campylobacter fetus. The dilutions were made individually for each bacterium, as well as in different concentrations needed to standardize the multiplex PCR test. DNA extractions of all solutions containing sperm and bacteria analyzed in this study were performed according to protocol described by Heinemann et al. (2000). The multiplex PCR products were analyzed by electrophoresis on 8% polyacrylamide gel and capillary electrophoretic separation system for automated equipment in the analysis of DNA fragments MegaBACE. We observed amplification of fragments of 193pb, 330pb, 415pb and 400bp from the DNA of B. abortus, L. pomona, H. somnus, C. fetus respectively. The analysis by capillary electrophoresis of multiplex PCR products of DNA for simultaneous detection of the four pathogens was observed by detecting the dilution of 10-3 bacteria / mL times the initial concentration of the stock solution of each bacterium. The multiplex PCR coupled with capillary electrophoresis was first used for the direct diagnosis of four pathogenic bacteria in semen, proving to be a rapid method to detect bacteria that cause reproductive disorders.
Download / View
  
 
Colégio Brasileiro de Patologia Animal CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico Coordenação de Aperfeiçoamento de Pessoal de Nível Superior ISI Web of Knowledge SciELO - Scientific Electronic Library Online Banco de Dados Bibliográficos da USP UnB - Universidade de Brasília UFRRJ - Universidade Federal Rural do Rio de Janeiro CFMV - Conselho Federal de Medicina Veterinária