Resultado da pesquisa (12)

Termo utilizado na pesquisa B-mode

#1 - B-mode and Doppler ultrasound of bitches’ kidneys with mammary neoplasia submitted to adjuvant chemotherapy

Abstract in English:

Mammary neoplasia represents the most frequently diagnosed type of neoplasia in bitches. Although surgical removal is the procedure of choice for therapeutic management, chemotherapy protocols appear as important allies and adjuvants. Despite the great advances that have occurred in the field of cancer therapy, the systemic repercussions of these drugs still impose important limitations on their use. In this sense, the development of increasingly targeted therapeutic protocols and preventive monitoring of patients represent important strategies to avoid possible complications – among them, Acute Kidney Injury (AKI). Routinely, ultrasound evaluation is used to identify morphological or metastatic variations in abdominal cavity organs. Acting complementary to the B-mode evaluation, Doppler mapping proves to be efficient in recognizing alterations in vascular hemodynamics. Therefore, the objective of the present study was to evaluate the use of B-mode and Doppler ultrasound to identify renal morphological and hemodynamic alterations in bitches with mammary neoplasia submitted to adjuvant chemotherapy protocols that associate gemcitabine with carboplatin. Thirteen bitches were included, without distinction of breed and between seven and 13 years of age. The animals were evaluated ultrasonographically at two different times during three consecutive chemotherapy cycles: before (T0) and one and a half hours after each cycle (T1), for 42 days. No morphological changes were observed in B-mode throughout the chemotherapy protocol. However, the Doppler velocimetry indices demonstrated statistical differences before (T0) and after (T1) the administration of the drugs. It was concluded that Doppler ultrasound could be used as a complementary method for monitoring the renal response of patients exposed to nephrotoxic drugs and potentially causing renal injury.

Abstract in Portuguese:

As neoplasias mamárias representam o tipo de neoplasma mais frequentemente diagnosticado em fêmeas da espécie canina. Embora a remoção cirúrgica seja o procedimento de eleição para a conduta terapêutica, os protocolos quimioterápicos aparecem como importantes aliados e adjuvantes. Apesar dos grandes avanços ocorridos na área da terapia oncológica, as repercussões sistêmicas destes fármacos ainda impõem importantes limitações ao seu uso. Neste sentido, o desenvolvimento de protocolos terapêuticos cada vez mais direcionados e o monitoramento preventivo dos pacientes representam estratégias importantes para evitar possíveis complicações - dentre elas, a injúria renal aguda (IRA). Rotineiramente, a avaliação ultrassonográfica é utilizada para identificação de variações morfológicas ou metastáticas em órgãos da cavidade abdominal. Atuando de forma complementar à avaliação em modo-B, o mapeamento Doppler mostra-se eficiente no reconhecimento de alterações na hemodinâmica vascular. Portanto, o objetivo do presente estudo foi avaliar a utilização da ultrassonografia modo-B e Doppler como método para identificação de alterações morfológicas e hemodinâmicas renais em cadelas com neoplasias mamárias submetidas a protocolos quimioterápicos adjuvantes que associam a gencitabina à carboplatina. Foram incluídas 13 fêmeas caninas, sem distinção quanto a raça e com idades entre sete e 13 anos. Os animais foram avaliados ultrassonograficamente em dois momentos distintos durante três ciclos quimioterápicos consecutivos: antes (T0) e uma hora e meia após a realização de cada ciclo (T1), totalizando 42 dias. Não foram observadas alterações morfológicas em modo-B ao longo do protocolo quimioterápico. Entretanto, os índices dopplervelocimétricos demonstraram diferenças estatísticas antes (T0) e após (T1) a administração dos fármacos. Concluiu-se que a ultrassonografia Doppler pode ser utilizada como método complementar para o monitoramento da resposta renal de pacientes expostos a fármacos nefrotóxicos e potencialmente causadores de injúrias renais.


#2 - Accuracy of B-mode ultrasonography for detecting malignancy in canine cutaneous neoplasms: preliminary results

Abstract in English:

The aim of this study was to verify the applicability and accuracy of B-mode ultrasonography in detecting malignancy in dog cutaneous neoplasms. Forty-two neoplasms (12 benign and 30 malignant) of mesenchymal, round cells, epithelial and melanocytic origins from 24 dogs of different breeds and ages were included. The ultrasound evaluation was performed with a linear multi-frequency transducer (7.0 to 12MHz), with frequency dependent on the mass dimension. Ultrasonographic characteristics of echogenicity (hypo/hyperechogenic), echotexture (homogeneous/heterogeneous), regularity, invasiveness in adjacent tissues were classified. Dimensions were also measured to calculate the depth/width ratio. Neoplasms were classified as malignant or benign after cytological and/or histopathological analysis and the results were associated with ultrasound characteristics. There was a significant association (P<0.05) between malignancy and echogenicity, echotexture and invasiveness in adjacent tissues, so that 84.6% of hypoechogenic neoplasms, 76.9% of heterogeneous masses and 88.2% of invasive neoplasms were classified as malignant. However, for all these associations, moderate predictive values were obtained, which may be due to the small experimental number included in this study. Therefore, although it has been observed that hypoechogenic, heterogeneous and invasive neoplasms were more prone to malignancy, these findings should be used with caution until new studies are developed with a greater number and variety of cutaneous neoplasms in dogs.

Abstract in Portuguese:

O objetivo deste estudo foi verificar a aplicabilidade e acurácia da ultrassonografia modo-B na detecção de malignidade em neoplasmas cutâneos de cães. Foram incluídos 42 neoplasmas (12 benignos e 30 malignos) de origens mesenquimal, células redondas, epitelial e melanocítica provenientes de 24 cães de diferentes raças e idades. O exame ultrassonográfico foi realizado com transdutor linear multifrequencial (7.0 a 12MHz), com frequência dependente da dimensão da massa. Foram classificadas características ultrassonográficas de ecogenicidade (hipo/hiperecogênicos), ecotextura (homogêneos/heterogêneos), regularidade, invasividade em tecidos adjacentes. As dimensões foram mensuradas para cálculo da razão profundidade/largura. Os neoplasmas foram classificados como malignos ou benignos após análise cito e/ou histopatológica e os resultados foram associados com as características ultrassonográficas. Verificou-se associação significativa (P<0.05) entre malignidade e ecogenicidade, ecotextura e invasividade em tecidos adjacentes, de forma que 84.6% dos neoplasmas hipoecogênicos, 76.9% das massas heterogêneas e 88.2% dos neoplasmas invasivos foram classificados como malignos. Entretanto, para todas essas associações, foram obtidos valores preditivos moderados, que podem ser decorrentes do baixo número experimental incluso neste estudo. Sendo assim, embora tenha sido observado que os neoplasmas hipoecogênicos, heterogêneos e invasivos tiveram maior propensão à malignidade, esses achados devem ser utilizados com cautela até novos trabalhos sejam desenvolvidos com maior número e variedade de neoplasmas cutâneos de cães.


#3 - Applicability of B-mode ultrasonography, ARFI elastography and contrast-enhanced ultrasound in the evaluation of chronic kidney disease in dogs

Abstract in English:

The objective of this study was to verify the applicability of B-mode ultrasonography, ARFI elastography and CEUS in the diagnosis of chronic kidney disease and its Stages in dogs. 24 healthy dogs and 28 with CKD were included. In B-mode, the echogenicity, echotexture and cortico-medullary ratio of the kidneys were verified. By elastography, the shear-wave velocity of the cortical (SWVcort) and medullary (SWVmed) regions were determined and tissue deformity was evaluated. Wash-in, wash-out and peak enhancement (TPic) of the contrast in the renal parenchyma were calculated and homogeneity, presence of filling gaps and distinction of filling phases were evaluated by CEUS. Changes in echogenicity, echotexture and cortico-medullary ratio were observed only in sick patients. There was an increase in SWVcort in CKD, with a cutoff point >2.91m/s. Healthy kidneys were non-deformable and 25% had changes in gray scales. There was an increase in wash-in and TPic, changes in filling characteristics, filling failures and difficulty in distinguishing between the Stages in CEUS in CKD. It was found that dogs with CKD 2, 3 and 4 had greater SWVcort and wash-in values than CKD 1. Elastographic and CEUS changes were observed in dogs with CKD, demonstrating the applicability of ultrasonographic techniques in their diagnosis.

Abstract in Portuguese:

O objetivo deste estudo foi verificar a aplicabilidade da ultrassonografia modo-B, elastografia ARFI e CEUS no diagnóstico da doença renal crônica e seus estágios em cães. Foram incluídos 24 cães saudáveis e 28 com DRC. Pelo modo-B, verificou-se ecogenicidade, ecotextura e relação córtico-medular dos rins. Pela elastografia, foram determinadas as velocidades de cisalhamento das regiões cortical (SWVcort) e medular (SWVmed) e foi avaliada a deformidade tecidual. Calculou-se os temos de wash-in, wash-out e pico de intensidade (TPic) do parênquima renal e avaliou-se homogeneidade, presença de falhas e distinção das fases de preenchimento por contraste por meio de CEUS. Alterações em ecogenicidade, ecotextura e relação córtico-medular foram observadas somente em pacientes doentes. Houve aumento da SWVcort na DRC, com ponto de corte >2.91m/s. Rins saudáveis foram não-deformáveis e 25% apresentou alterações nas escalas de cinza. Houve aumento do wash-in e TPic, alterações nas características de preenchimento, falhas e dificuldade para distinguir as fases de preenchimento do contraste nos rins com DRC. Verificou-se que cães com DRC graus 2, 3 e 4 tiveram valores de SWVcort e wash-in maiores que cães com DRC grau 1. Foram obsrervadas alterações elastográfica e de CEUS em cães com DRC, demonstrando a aplicabilidade destas técnicas ultrassonográficas no seu diagnóstico.


#4 - B-mode ultrasonography and gray scale histogram for evaluation of the nuchal ligament in Quarter horse

Abstract in English:

The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: “baby” (1), “sobreano” (2) and “adult” (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.

Abstract in Portuguese:

O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonograficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: “baby” (1), “sobreano” (2) e “adulto” (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis “Mean” e “Mode” entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.


#5 - B-mode and Doppler ultrasonography in the assessment of the common carotid arteries of equines and mules and the relation with body mass, age and neck circumference

Abstract in English:

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.

Abstract in Portuguese:

Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.


#6 - Abdominal B-mode and Doppler ultrasonography of chemically restrained agouti (Dasyprocta prymnolopha Wagler, 1831)

Abstract in English:

Agoutis are small-sized wild animals whose body weight can reach up to 4kg, and are found throughout Brazil. They are considered important seed dispersers, especially for big trees and there are species that rely almost exclusively on these animals for their territorial distribution. The objective of the present study was B scan and Doppler ultrasound characterization of the abdominal organs of healthy agoutis reared in captivity. Fifteen agoutis, chemically restrained, were used from the Nucleus for Wild Animal Studies and Conservation (Núcleo de Estudos e Preservação de Animais Silvestres - NEPAS), CCA-UFPI, submitted to B scan and Doppler ultrasound examination. The urinary bladder wall was hyperechogenic, thin, smooth and regular throughout its anatomic path, with 0.09±0.03cm mean thickness. The kidneys showed fine and homogeneous echotexture, preserved global echogenicity, hyperechogenic in relation to the spleen and isoechogenic or discreetly hyperechogenic in relation to the liver. The spectral Doppler trace showed systolic and diastolic peaks, wide and thread-like, with low flow resistance and a continuous and full diastolic portion that decreased gradually during the diastole (75.83±1.42cm/s, for the right kidney and 80.43±1.22cm/s, for the left kidney). The right adrenal gland was 0.61-1.18cm long and 0.17-0.32cm in diameter, while the left adrenal gland was 0.62-1.16 long with 0.14-0.25cm diameter. The agouti spleen was filiform in shape, with pointed poles and 1.02±0.18cm in diameter. The agouti liver occupied all the abdominal cavity cranial space in direct contact with the diaphragm. The intrahepatic vascular flow allowed individualization of the portal vein (PV) and hepatic vein (HV). The portal veins were distinguished from the hepatic veins mainly by their wall echogenic pattern. The pancreas was 0.51±0.1 cm thick and the pancreatic duct measured 0.12±0.02cm. The stomach was placed to the left the spleen and to the right of the proximal intestine and the transversal colon and the walls were 0.16±0.05cm thick. The abdominal aorta was 0.43±0.04cm in diameter and showed 95.2±2.16cm/s vascular flow. This study characterized agouti organs and abdominal blood vessels by B scan and Doppler ultrasound, that permitted definition of the size, shape, position, echogenicity and echotexture of the anatomic constituents and established reference values for the vascular network and blood flow in the species.

Abstract in Portuguese:

As cutias são animais silvestres de pequeno porte, cujo peso corpóreo pode chegar até 4kg, e existem em todo território brasileiro. São considerados importantes dispersores de sementes, especialmente para árvores de grande porte, existindo espécies que dependem quase que exclusivamente destas para sua distribuição territorial. Este trabalho teve por objetivo a caracterização ultrassonográfica modo B e Doppler dos órgãos abdominais de cutias hígidas criadas em cativeiro. Foram utilizadas 15 cutias, contidas quimicamente, oriundas do Núcleo de Estudos e Preservação de Animais Silvestres – NEPAS, CCA-UFPI, submetidas a exame ultrassonográfico em modo B e Doppler. A parede da vesícula urinária presentou-se hiperecogênica, fina, lisa e regular em todo seu trajeto anatômico, com espessura média de 0,09±0,03cm. Os rins demonstraram ecotextura fina e homogênea, ecogenicidade global preservada, hipoecogênico em relação ao baço e isoecogênico ou discretamente hipoecogênico em relação ao fígado. O traçado em Doppler espectral mostrou pico sistólico e diastólico, amplo e afilado, exibindo baixa resistência de fluxo, com uma porção diastólica contínua e cheia, que diminui gradativamente no decorrer da diástole (75,83±1,42cm/s para o rim direito e 80,43±1,22 cm/s para o esquerdo. A adrenal direita apresentou uma variação de comprimento entre 0,61 a 1,18cm e diâmetro variando entre 0,17 a 0,32cm, enquanto a adrenal esquerda evidenciou comprimento de 0,62 a 1,16 e diâmetro de 0,14 a 0,25cm. O baço das cutias mostrou formato filiforme, com polos pontiagudos e diâmetro de 1,02±0,18cm. O fígado da cutia ocupa todo o espaço cranial da cavidade abdominal, em contato direto com o diafragma. O fluxo vascular intrahepático permitiu individualizar as veias porta (VP) e veias hepáticas (VH). As veias porta foram distinguidas, particularmente pelo padrão ecogênico de suas paredes, quando comparadas com as veias hepáticas. A espessura do pâncreas foi de 0,51±0,1cm e o ducto pancreático mediu 0,12±0,02cm. O estômago relaciona-se à esquerda com o baço e a direita com o duodeno proximal e colón transverso. Sua espessura de parede mensurada foi de 0,16±0,05cm. A aorta abdominal possui diâmetro de 0,43±0,04cm e fluxo vascular de 95,2±2,16cm/s. Este estudo caracterizou os órgãos e vasos sanguíneos abdominais de cutias, por meio de ultrassonografia modo B e Doppler, o que permitiu definir o tamanho, formato, posição, ecogenicidade, ecotextura dos constituintes anatômicos, além de estabelecer valores de referência para a rede vascular e fluxo sanguíneo na espécie.


#7 - Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

Abstract in English:

B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.

Abstract in Portuguese:

O exame ultrassonográfico modo-B é uma importante ferramenta diagnóstica que permite caracterizar a anatomia interna dos órgãos e, complementada pelo exame modo Doppler, possibilita realizar a avaliação hemodinâmica vascular, aumentando a acurácia diagnóstica. Desta forma, este trabalho teve como objetivo a caracterização ultrassonográfica e mensuração dos segmentos do bulbo ocular modo-B, assim como a avaliação da artéria oftálmica externa pelo Doppler colorido e pulsado. Foram avaliados 60 bulbos oculares de 30 cães de diferentes raças utilizando transdutor microconvexo de 8,5MHz. Inicialmente foi realizada biometria por meio do exame em modo-B dos seguintes seguimentos: comprimento axial (M1), profundidade da câmara anterior (M2), espessura da lente (M3), comprimento da lente (M4), profundidade da câmara vítrea (M5), comprimento do disco óptico (M6) e diâmetro do nervo óptico (M7). A artéria oftálmica externa foi identificada pelo Doppler colorido e seu fluxo foi avaliado por meio do Doppler pulsado, sendo mensurados: velocidade do pico sistólico (VPS), velocidade diastólica final (VDF), índice de resistividade (IR) e índice de pulsatilidade (IP). Não foi verificada diferença estatística para os valores biométricos dos seguimentos oculares entre os olhos direito e esquerdo (p>0,05). A profundidade da câmera vítrea (M5), mostrou-se a variável biométrica com maior simetria bilateral, variando entre 0,79 a 0,87cm e 0,78 a 0,86cm para o olho direito e esquerdo, respectivamente. A artéria oftálmica foi visibilizada sobre o nervo óptico em direção ao bulbo ocular, com fluxo marcado em vermelho. Não houve diferença estatística significativa entre os valores Dopplervelocimétricos da artéria oftálmica entre do olho direito e esquerdo dos animais avaliados (p>0.05). O índice de resistividade (IR) médio evidenciou valores médios sendo igual a 0,63±0,03, bilateralmente. A velocidade basal média foi 17,50cm/s e 18,18cm/s no pico sistólico e 6,21cm/s e 6,68cm/s no final da diástole, para os olhos direito e esquerdo, respectivamente. A caracterização anatômica, biométrica e hemodinâmica utilizando o exame ultrassonográfico modo-B e as modalidades do Doppler permitiram a avaliação ultrassonográfica e Dopplervelocimétrica dos componentes do bulbo ocular nos cães de diferentes raças, podendo ser utilizados na rotina clínica oftalmológica para identificação de patologias oculares.


#8 - B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media, 37(7):759-772

Abstract in English:

ABSTRACT.- Martín C.M., Kogika M.M., Miyashiro S.I. & Fonseca-Pinto A.C.B.C. 2017. [B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media.] Ultrassonografia modo B e Doppler na avaliação renal de cães submetidos à tomografia computadorizada após administração intravenosa de diferentes meios de contraste iodado. Pesquisa Veterinária Brasileira 37(7):759-772. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Contrast-induced nephropathy (CIN) is an acute disease, secondary to intravascular administration of iodinated contrast media (ICM). The most important mechanisms of this nephropathy are intrarenal prolonged vasoconstriction, medular hypoxia, and ischemia associated with renal tubular damage due to contrast cytotoxicity. Owing to the limited information available in veterinary literature regarding these mechanisms this study aims to compare the renal effects of intravenous administration of two nonionic ICM of different osmolarities in groups of dogs with risk factors for CIN development, by using a B-mode, color, power- and pulsed-wave Doppler ultrasonography, and other laboratory tests, in order to indirectly estimate the nephrotoxic potential of each contrast. The following two groups were established according to the nonionic ICM used: the GIH group [11 dogs administered iohexol (low osmolarity)] and the GID group [seven dogs administered iodixanol (iso-osmolarity)]. Both the groups were administered the same dose (600mgI/kg/IV). The following renal aspects were evaluated before administration of ICM (baseline) and after 1h30min, 24h, and 48h: renal morphometry (length and volume), renal morphology, cortical echogenicity, renal perfusion, and intrarenal vascular resistance (resistive and pulsatility indices); in addition, urinalysis was performed, and urinary gamma-glutamyl transferase:creatinine ratio (GGT:C), urinary protein:creatinine ratio (UPC), and serum creatinine were also measured. Both groups showed similar characteristics with respect to the length, volume, UPC ratio, urinalysis, and serum creatinine levels. No similarity was observed with respect to the pulsatility index (PI) in both the groups and there were no significant differences between baseline and 1h30min, 24h and 48h time points. With respect to the IR and urinary GGT:C, both groups showed no similarity, and significant increases were observed in the resistive index (RI) and urinary GGT:C only in the GIH group, 1h30min after contrast administration. In conclusion, RI can be used to monitor intrarenal hemodynamics, and along with the urinary GGT:C, revealed that iohexol had higher nephrotoxic potential than iodixanol. Thus, iodixanol is considered a favorable option for dogs with risk factors for CIN development.

Abstract in Portuguese:

RESUMO.- Martín C.M., Kogika M.M., Miyashiro S.I. & Fonseca-Pinto A.C.B.C. 2017. [B-mode and Doppler ultrasonography in the renal evaluation of dogs undergoing computed tomography after intravenous administration of different iodinated contrast media.] Ultrassonografia modo B e Doppler na avaliação renal de cães submetidos à tomografia computadorizada após administração intravenosa de diferentes meios de contraste iodado. Pesquisa Veterinária Brasileira 37(7):759-772. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br A nefropatia induzida por contraste (NIC) é uma doença de caráter agudo, secundária à administração intravascular de meios de contraste iodado (MCI). Dentre os mecanismos fisiopatológicos desta enfermidade destacam-se a vasoconstrição intrarrenal prolongada, consequente redução da perfusão renal, hipóxia e isquemia medulares, associada ao dano tubular renal devido à citotoxicidade do contraste. Frente à existência de poucas informações relacionadas a estes mecanismos na literatura médico-veterinária, objetivaram-se comparar os efeitos renais da administração intravenosa de MCI não iônicos de diferentes osmolaridades, em grupos de cães com fatores de risco para o desenvolvimento da NIC, por meio das avaliações ultrassonográficas modo B, Doppler colorido, de amplitude e pulsado, pareada aos exames laboratoriais, a fim de estimar indiretamente o potencial nefrotóxico de cada contraste. Constituíram-se dois grupos de acordo com o MCI utilizado: o grupo GIH [11 cães receberam iohexol (baixa osmolaridade)] e o grupo GID [sete cães receberam iodixanol (isosmolar)]. Administrou-se a dose de 600mgI/kg/IV em ambos. Avaliaram-se os seguintes aspectos renais antes da administração do MCI (momento basal) e após 1h30min, 24 horas e 48 horas: morfometria (comprimento e volume), morfologia, ecogenicidade cortical e perfusão renais e resistência vascular intrarrenal (índices hemodinâmicos de resistividade e pulsatilidade). Realizou-se ainda exame de urina e se mensuraram as razões gama-glutamil transferase:creatinina (GGT:C) e proteína:creatinina (RPC) urinárias e a concentração sérica de creatinina. Os grupos apresentaram comportamentos similares para comprimento, volume, RPC, exame de urina e creatinina sérica. Em relação ao índice de pulsatilidade (IP), os grupos apresentaram comportamentos não similares, mas sem diferenças significantes entre o momento basal e os demais. Para o índice de resistividade (IR) e a razão GGT:C urinária, os grupos revelaram comportamentos não similares e se constataram aumentos significantes do IR e da razão GGT:C urinária no período de 1h30min após a administração do contraste, somente para o grupo que recebeu iohexol. Concluiu-se que o IR pode ser utilizado para monitorar a hemodinâmica intrarrenal, visto que junto com a razão GGT:C urinária, demonstrou a existência de maior potencial nefrotóxico do iohexol, quando comparado ao iodixanol. Dessa forma, considera-se o uso do iodixanol, opção favorável para cães com fatores de risco para o desenvolvimento da NIC.


#9 - B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age, 36(6):545-550

Abstract in English:

ABSTRACT.- Santarosa B.P., Ferreira D.O.L., Belotta A.F., Dias A., Mamprim M.J. & Gonçalves R.C. 2016. B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age. Pesquisa Veterinária Brasileira 36(6):545-550. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus Botucatu, Distrito de Rubião Junior s/n, Botucatu, SP 18618-970, Brazil. E-mail: biancasantarosavet@gmail.com There is no standardization in the literature of kidney length in sheep at different ages, as there are few studies about the access with the Doppler triplex ultrasound for the renal vascularization in this species. Eighty healthy sheep of three age groups of Ile de France and White Dorper breed were used: 20 lambs, 30 yearlings and 30 adults (8 rams and 22 ewes). Renal healthiness of the animals was confirmed by serum biochemical tests of urea and creatinine, and by observation of renal architecture with conventional ultrasound, besides measurement of vital parameters. A portable ultrasound (My LabTM30 Vet Gold Esaote®, Esaote Healthcare) device was used, with a convex transducer with 3.5MHz frequency. After identification of the kidneys in two-dimensional mode, the measurement of length in the sagittal section was performed in all sheep (n=80). Then color Doppler was activated for visualization of renal and interlobar arteries of the right kidney, and the resistivity index (RI) of the yearlings (n=30) and ewes (n=22) was measured. Biochemical tests remained within normal limits and renal architecture was preserved. The values &#8203;&#8203;of the right and left renal length were different between the groups, increasing with age (4.34cm and 4.31cm in lambs; 6.08cm and 6.23cm in yearlings; 7.57cm and 7.37cm in adults, respectively). Median values of RI of the renal artery were statistically different (p<0.05) between the groups of yearlings (0.57) and ewes (0.52). The median RI of the interlobar artery was similar in yearlings (0.58) and ewes (0.54).

Abstract in Portuguese:

RESUMO.- Santarosa B.P., Ferreira D.O.L., Belotta A.F., Dias A., Mamprim M.J. & Gonçalves R.C. 2016. B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age. [Ultrassonografia Modo-B e Doppler pulsado dos rins de ovinos hígidos de acordo com a idade.] Pesquisa Veterinária Brasileira 36(6):545-550. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus Botucatu, Distrito de Rubião Junior s/n, Botucatu, SP 18618-970, Brazil. E-mail: biancasantarosavet@gmail.com Não há na literatura padronização do comprimento renal de ovinos, em diferentes idades, assim como existem poucos trabalhos sobre a vascularização renal nesta espécie. Utilizaram-se no total 80 ovinos hígidos de três faixas etárias, das raças Ile de France e White Dorper: 20 cordeiros, 30 borregos e 30 adultos (8 carneiros e 22 ovelhas). A higidez renal dos animais foi comprovada por exames bioquímicos séricos de ureia e creatinina e pela observação da arquitetura renal. Utilizou-se aparelho de Ultrassom portátil (My LabTM30 Vet Gold Esaote®, Esaote Healthcare), com transdutor convexo de frequência de 3,5MHz. Após identificação dos rins no modo bidimensional, foi realizada a mensuração do comprimento no corte sagital em todos os ovinos. Em seguida, Doppler colorido foi ativado para visualização das artérias renal e interlobar do rim direito, e mensurou-se o índice de resistividade dos borregos (n=30) e ovelhas (n=22). Os exames bioquímicos permaneceram dentro da normalidade e a arquitetura renal estava preservada. Os valores do comprimento renal direito e esquerdo foram diferentes entre os grupos, sendo crescente conforme a idade (4,34 e 4,31 em cordeiros, 6,08 e 6,23 em borregos, 7,57 e 7,37 em adultos). As medianas do IR da artéria renal foi estatisticamente diferente (p<0,05) entre os grupos dos borregos (0,57) e ovelhas (0,52). A mediana do IR da artéria interlobar não apresentou diferença entre borregos (0,58) e ovelhas (0,54).


#10 - B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation, 35(9):801-810

Abstract in English:

ABSTRACT.- Martín C.M., Souto C.K., Ferrante B. & Fonseca-Pinto A.C.B.C. 2015. [B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation.] Ultrassonografia modo B e Doppler na avaliação renal de cães após administração intravenosa de meio de contraste iodado: validação da técnica. Pesquisa Veterinária Brasileira 35(9):801-810. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Iodinated contrast media can provide hemodynamic effects related to prolonged intrarenal vasoconstriction and reduced perfusion, predisposing to hypoxia and medular ischemia. Changes in the renal vascular resistance may represent the first sign of impaired renal function. Pulsed wave Doppler sonography is low cost, non-invasive and allows renal hemodynamic evaluation by resistivity (RI) and pulsatility (PI) indices. However in dogs, spectral Doppler waveform may be hard to obtain due to scanning difficulties and lack of signal Doppler. This fact occurs mostly in the right kidney because of its cranial and dorsal position in the abdominal cavity and may prolong the exam. The purpose of this study is to prove that the pulsed wave Doppler interrogation of the canine left kidney intrarenal arteries represent the renal hemodynamic effects of intravenous administration of iodinated contrast media and is not necessary to perform the exam in both kidneys. Right and left kidneys of six adult dogs were evaluated at four different times: before intravenous contrast infusion and after 1.5 hours, 24 hours and 48 hours, subjectively by using renal morphology, cortical echogenicity and renal perfusion, and objectively by using renal length, renal volume and intrarenal vascular resistance (RI and PI). No significant differences were noted between the parameters assessed by B mode and Doppler sonography of the right and left kidney in each evaluated moment. Thus, it was noted that pulsed wave Doppler sonographic evaluation of the left kidney represented the renal hemodynamic response of intravenous iodinated contrast media administration, only if both kidneys presented similar morphometry, morphology, cortical echogenicity, and perfusion during the first assessment.

Abstract in Portuguese:

RESUMO.- Martín C.M., Souto C.K., Ferrante B. & Fonseca-Pinto A.C.B.C. 2015. [B-mode and Doppler ultrasonography in the renal evaluation of dogs after intravenous administration of iodinated contrast media: technical validation.] Ultrassonografia modo B e Doppler na avaliação renal de cães após administração intravenosa de meio de contraste iodado: validação da técnica. Pesquisa Veterinária Brasileira 35(9):801-810. Programa de Pós-Graduação em Clínica Cirúrgica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade de São Paulo, Av. Prof. Orlando Marques de Paiva 87, Cidade Universitária, São Paulo, SP 05508-270, Brazil. E-mail: cmmartin@uol.com.br Meios de contraste iodado podem promover efeitos hemodinâmicos relacionados à vasoconstrição intrarrenal prolongada e redução da perfusão, predispondo à hipóxia e isquemia medular. Alterações de resistência vascular renal podem representar os primeiros sinais de mudança funcional desse órgão. A técnica Doppler pulsado é considerada acessível, não invasiva e permite avaliar a dinâmica vascular dos rins, por meio da aferição dos índices de resistividade (IR) e pulsatilidade (IP). Contudo, na espécie canina, a aquisição de traçados espectrais pode ser penosa devido às dificuldades de varredura e captação de sinal Doppler, sobretudo em relação ao rim direito, devido à sua localização dorsocranial na cavidade abdominal, o que prolonga substancialmente a realização do exame. O objetivo deste estudo é comprovar que a avaliação Doppler pulsado das artérias intrarrenais do rim esquerdo de cães representa a repercussão hemodinâmica renal da administração intravenosa de meios de contraste iodado não sendo necessária a realização do exame nos dois rins. Foram avaliados ambos os rins de seis cadelas adultas em quatro momentos distintos: antes da infusão intravenosa do contraste radiológico e após 1,5 horas, 24 horas e 48 horas, por meio da análise subjetiva da morfologia, ecogenicidade cortical e grau de perfusão renais e análise objetiva do comprimento, volume e resistência vascular intrarrenais (IR e IP). Os parâmetros avaliados ao modo B e Doppler dos rins direito e esquerdo não apresentaram diferenças estatisticamente significativas entre si em cada momento avaliado. Assim, constatou-se que o exame ultrassonográfico Doppler pulsado do rim esquerdo representou a repercussão hemodinâmica renal da aplicação intravenosa de meios de contraste iodado, desde que morfometria, morfologia, ecogenicidade cortical e perfusão de ambos os rins fossem consideradas semelhantes na abordagem ultrassonográfica inicial.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV