Resultado da pesquisa (2)

Termo utilizado na pesquisa Biobanco

#1 - Veterinary disease-oriented Biobanking for biomolecular analysis based on frozen tumor biopsies, cell culture and forensic tissues

Abstract in English:

Collecting and analyzing biological specimens leads to unprecedented opportunities for assessing and understanding the complex networks of interactions between biomolecules, and the functional and clinical consequences of their alterations. In this context, the Tissue Bank plays a key role in life science research and development, making its implementation in veterinary medicine essential for developing new research, especially in the forensic and tumor fields. In total, 52 tissues were collected, 15 forensic samples, 25 neoplasms, and 12 cell cultures. The storage, freezing, data management protocols, and the quality of these samples were analyzed. In the same way, the quality of the RNA and DNA in the short and long term was evaluated. The quality of the genetic material was confirmed by polymerase chain reaction. For data comparisons, non-parametric tests were used, with a significance level of p˂0.05. The measures adopted in the Tissue Bank for obtaining and handling the samples and for controlling and guaranteeing the quality were considered adequate, as they enabled optimal preservation of the integrity of the genetic material, a relevant factor for the use of tumor samples and forensic samples stored in the Biobank, thus contributing to future molecular research in the area of pathology and investigations of crimes against fauna.

Abstract in Portuguese:

A coleta e análise de espécimes biológicos é necessária porque abre oportunidades sem precedentes para avaliar e conhecer as complexas redes de interações entre biomoléculas, e as consequências funcionais e clínicas das suas alterações. Nesse contexto, o Banco de Tecidos desempenha um papel fundamental na investigação e desenvolvimento das ciências da vida, tornando a sua implementação na área da medicina veterinária essencial para o desenvolvimento de novas pesquisas em especial na área forense e tumoral. Foram coletadas 52 amostras de tecidos, 15 de amostras forenses, 25 neoplasias e 12 culturas celulares. Nesses tecidos, foram analisados os protocolos de armazenamento, congelamento, gerenciamento de dados e qualidade das amostras. Da mesma forma, foi analisada a qualidade do RNA e do DNA a curto e longo prazo e a qualidade do material genético foi confirmada pela reação em cadeia da polimerase. Para comparação dos dados, foram utilizados testes não paramétricos, com nível de significância p˂0,05. As medidas adotadas no Banco de Tecidos para obtenção e manuseio das amostras, controle e garantia da qualidade foram adequadas, pois possibilitaram a preservação ideal da integridade do material genético, fator relevante para a utilização de amostras tumorais e forenses armazenadas no Biobanco, contribuindo assim para futuras pesquisas moleculares na área de patologia e investigação de crimes contra a fauna.


#2 - Use of the ACP® and BTS extenders for cooling at 15°C white-lipped peccary (Tayassu pecari) semen

Abstract in English:

Knowledge about reproduction of white-lipped peccary is of great importance to assist with the conservation of this species and enable its rational use in captivity. This study aimed to evaluate the effect of ACP-103®, ACP-116® and BTS semen extenders on sperm viability during cooling of Tayassu pecari semen. Five ejaculates from four adult males were chilled. The animals were submitted to the protocols of sedation and anesthesia for semen collection by the electroejaculation method. After collection, the semen was macro- and microscopically assessed and diluted to reach 35x106 spermatozoa/mL in each of the three different extenders tested. The fresh-extended semen was packed in a BotuFLEX® thermal box to keep samples at 15°C for 24 hours. After cooling, the following semen parameters were analyzed: sperm motility, functional and structural integrity of sperm membranes, mitochondrial activity, chromatin condensation, and the thermoresistance test was performed. The parameters sperm motility, structural and functional integrity of sperm membranes, mitochondrial activity, and chromatin condensation were preserved after use of the extenders tested, and were similar to those of in natura semen (p>0.05). Curvilinear velocity (VCL) (p<0.05) was the only parameter with reduced values after cooling regardless of the extender used. The percentage of sperm with normal morphology was greater in samples cooled using the BTS extender (p<0.05). The ACP-103®, ACP-116® and BTS extenders can be used for the cooling and preservation of white-lipped peccary semen at 15°C for 24 hours.

Abstract in Portuguese:

Para auxiliar na conservação da espécie e permitir o uso racional do queixada em cativeiro é de grande importância o conhecimento sobre a reprodução da espécie. Objetivou-se avaliar o efeito dos diluidores de sêmen ACP-103®, ACP-116® e BTS na viabilidade espermática durante a refrigeração do sêmen do Tayassu pecari. Foram refrigerados cinco ejaculados provenientes de quatro machos adultos. Os animais foram contidos com auxílio de puçá e submetidos ao protocolo de sedação e anestesia para realização da coleta de sêmen pelo método da eletroejaculação. Depois da coleta, o sêmen foi avaliado macro e microscopicamente e diluído para atingir 35x106 espermatozoides/mL em cada um dos três diferentes diluidores testados. O sêmen diluído foi acondicionado em caixa térmica BotuFLEX® para manter as amostras a 15°C por um período de 24 horas. Depois da refrigeração, os espermatozoides foram avaliados quanto aos parâmetros de movimento espermático, integridade funcional e estrutural das membranas espermáticas, atividade mitocondrial, condensação da cromatina e teste de termorresistência. Os diluidores testados preservaram as características cinéticas, a integridade estrutural e funcional das membranas espermáticas, a atividade mitocondrial e a condensação da cromatina semelhante ao sêmen in natura (P>0,05). O único parâmetro que reduziu com o processo de refrigeração independente do diluidor utilizado foi a Velocidade Curvilinear (VCL) (P<0,05). Foi observado aumento do percentual de espermatozoides morfologicamente normais nas amostras refrigeradas em BTS (P<0,05). Os diluidores ACP-103®, ACP-116® e BTS podem refrigerar e conservar o sêmen de queixada a 15°C por 24 horas.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV