Resultado da pesquisa (7)

Termo utilizado na pesquisa ECG

#1 - Non-invasive ECG recording and QT interval correction assessment in anesthetized rats and mice

Abstract in English:

Rats and mice are the most common species used in experimental cardiac electrophysiology studies. Electrocardiogram (ECG) recording shows paramount importance for monitoring arrhythmias and cardiac function in several disease models, including QT syndrome. However, the lack of standardized reference values and QT correction formula for different animal species and lineages represent a challenge for ECG interpretation. The aim of this study is to provide an improved method for ECG recording, establishing reference range values and determine the QT formulas with higher correlation to heart rate (HR). A total of 10 Wistar rats, 10 Swiss mice, 10 C57BL/6 mice and 10 FVB/NJ mice were used in the study. Animals were submitted to anesthesia with isoflurane and ECG recording was performed using a six-channel non-invasive electrocardiograph. QT was corrected using the following formulas: Bazzett, Fridericia, Mitchell, Hodges, Van der Water and Framingham. Normal range values for ECG parameters were established in all animals studied. Pearsons’ correlation defined Hodges formula as the most suitable for QT correction. This study demonstrated an improved method of ECG recording with reference values for Swiss, FVB/NJ, C57BL/6 mice, and Wistar rats. Hodges’ formula was the most effective formula for QT correction in rodents, whereas Bazett’s and Friderica formulas were ineffective for such animals. The present work contributes to arrhythmias investigation in experimental cardiology and may reduce misinterpretations in rodents’ ECG

Abstract in Portuguese:

Ratos e camundongos são as espécies mais comumente utilizadas em estudos experimentais de eletrofisiologia cardíaca. O registro do eletrocardiograma (ECG) é de suma importância para o monitoramento de arritmias e função cardíaca em vários modelos de patologias. No entanto, a falta de valores de referência padronizados e a fórmula de correção do QT para diferentes espécies e linhagens animais representam um desafio para a interpretação do ECG. O objetivo deste estudo é fornecer um método melhorado para o registro de ECG, estabelecendo valores de referência e determinar as fórmulas QT com maior correlação com a freqüência cardíaca (FC). Um total de 10 ratos Wistar, 10 camundongos Swiss, 10 camundongos C57BL/6 e 10 camundongos FVB/NJ foram utilizados no estudo. Os animais foram submetidos à anestesia com isoflurano e o registro de ECG foi realizado com eletrocardiógrafo não invasivo de seis canais. O QT foi corrigido usando as seguintes fórmulas: Bazzett, Fridericia, Mitchell, Hodges, Van der Water e Framingham. Os valores da normalidade para os parâmetros do ECG foram estabelecidos em todos os animais estudados. A correlação de Pearson definiu a fórmula de Hodges como a mais adequada para a correção do QT. Este estudo demonstra um método melhorado de registro de ECG com valores de referência para camundongos Swiss, FVB/NJ, C57BL/6 e Wistar. A fórmula de Hodges foi a mais eficaz para correção de QT em roedores, enquanto as fórmulas de Bazett e Friderica apresentaram valores mais baixos de correlação. O presente trabalho contribui para a investigação de arritmias em cardiologia experimental e pode reduzir interpretações erradas no ECG de roedores.


#2 - Effect of eCG on the follicular dynamics and vascularization of crossbred cows with different circulating progesterone concentrations during synchronization of ovulation in an FTAI protocol

Abstract in English:

This study aimed to evaluate the effect of treatment with equine chorionic gonadotrophin (eCG) on the follicular dynamics and function of crossbred cows with different circulating progesterone (P4) concentrations during synchronization of ovulation in a fixed-time artificial insemination (FTAI) protocol. To this end, 30 crossbred cows were submitted to a pre-synchronization protocol to ensure that all of them presented corpus luteum (CL) at the beginning of the protocol, and were evaluated by transrectal ultrasonography (TRUS) to verify the presence of CL. After that, the animals underwent an ovulation synchronization protocol and evaluation of follicular dynamics and vascularization by B-mode and power-Doppler ultrasound (US). High plasma P4 concentrations at the time of ovulation synchronization negatively influenced follicle diameter on day 10 (D10), preovulatory follicle diameter, and preovulatory follicle wall vascularization area (p<0.05). Cows with high P4 concentration at the time of ovulation synchronization that were treated with eCG showed follicle diameter on D10 and preovulatory follicle diameter and wall vascularization area (p>0.05) similar to those of animals with low P4 concentration at the time of ovulation synchronization. Therefore, high P4 concentrations at the time of ovulation synchronization negatively influence follicular diameter and vascularization, and eCG can be used as a strategy to favor better follicular and luteal response in crossbred cows with high P4 concentrations submitted to an FTAI protocol.

Abstract in Portuguese:

Objetivou-se neste estudo avaliar o efeito do tratamento com gonadotrofina coriônica equina (eCG) sobre a dinâmica e função folicular em fêmeas mestiças com diferentes concentrações circulantes de P4 durante a sincronização da ovulação em um protocolo de IATF. Para tanto, foram utilizadas 30 fêmeas mestiças e submetidas a um protocolo de pré-sincronização para garantir que todos os animais apresentassem corpo lúteo (CL) no início do protocolo, sendo avaliadas por ultrassonografia (US) transretal para a verificação da presença ou não de CL. Em seguida foram submetidas a um protocolo de sincronização da ovulação e avaliação da dinâmica e vascularização folicular por ultrassonografia (US) em modo B e Doppler colorido. Altas concentrações de P4 no momento da sincronização da ovulação impactaram negativamente no diâmetro do folículo no D10, o diâmetro do folículo pré-ovulatório e na área de vascularização da parede do folículo pré-ovulatório (P<0,05). As vacas com alta concentração de P4 no momento da sincronização da ovulação e que foram tratadas com eCG apresentaram diâmetro do folículo no D10 e no diâmetro e a área de vascularização da parede do folículo pré-ovulatório (P>0,05), semelhantes às vacas que com baixa concentração de P4 no momento da sincronização da ovulação. Conclui-se que elevadas concentrações de P4 no momento da sincronização da ovulação impactam negativamente no diâmetro e vascularização folicular e que o eCG pode ser utilizado como uma estratégia para favorecer uma melhor resposta folicular e luteal em fêmeas mestiças com altas concentrações de P4 submetidas a um protocolo de IATF.


#3 - Efficacy of the double PGF2 alpha dose-eCG association in proestrus of crossbred dairy cows submitted to IATF, 38(8):1518-1527

Abstract in English:

ABSTRACT.- Rodrigues A.S., Silva M.A.A., Brandão T.O., Nascimento A.B., Bittencourt R.F., Chalhoub M., Bittencourt T.C.B.S.C. & Ribeiro Filho A.L. 2018. [Efficacy of the double PGF2 alpha dose-eCG association in proestrus of crossbred dairy cows submitted to IATF.] Eficácia da associação dupla dose PGF2 alfa-eCG no proestro de vacas leiteiras mestiças submetidas à IATF. Pesquisa Veterinária Brasileira 38(8):1518-1527. Centro Multidisciplinar Campus Barra, Universidade Federal do Oeste da Bahia, Avenida 23 de Agosto 860, Centro, Barra, BA 47100-000, Brazil. E-mail: alexandra.rodrigues@ufob.edu.br The study aimed to evaluate the effect of one or two prostaglandin doses F2&#945; (PGF2a) with or without equine chorionic gonadotropin (eCG) in the follicular dynamics, the preovulatory luteal function, as well as the structural and functional characteristics post-ovulatory of the corpus luteum (CL) in cyclic crossbred females subjected to a fixed time artificial insemination (FTAI) protocol. For this, 29 multiparous 3/4 Gyr x Holstein cows were subjected to transrectal ultrasound examination (US) and upon detection of CL initiated a FTAI protocol on day called zero (D0) by the insertion of progesterone implant (P4) associated with the application of 2.0mg estradiol benzoate. On D7, these animals received 12.5mg of dinoprost tromethamine. At D9 happened the removal of the P4 devices and was applied 0.6mg of estradiol cypionate. At that time, the females were divided into the following treatments: control group (n=7) – which received 2.5mL of saline solution, 2PGF group (n=7) – received 12.5mg of dinoprost tromethamine, eCG group (n=7) - was administered 300IU eCG and eCG+2PGF group (n=8) – which received 300 IU eCG and 12.5mg of dinoprost tromethamine. To assess follicular dynamics were performed US scans B-mode and power doppler (Mindray Z5, Shenzhen, China) each 12h on D7 until the time of ovulation or until 96h after removal of the P4 implants, considering the follicular diameter (DFOL), the area of the follicular wall (AFOL) and the blood perfusion area of the follicular wall (VFOL). Concomitant with each test, blood samples were collected to determine the serum concentration of P4 preovulatory by chemiluminescence methodology. In D24 had held US B-mode and doppler to analyse the luteal diameter (DCL), luteal area (ACL) and blood perfusion area CL (VCL). Also, a blood sample was collected to determine the serum concentration of P4 post-ovulatory. All data was evaluated by Two-way ANOVA and repeated measures analysis considering the effects of eCG, 2PGF and eCG*2PGF, P<0.05. There was not significant difference between the synchronization protocols for DFOL, AFOL and VFOL variables over time of follicular dynamics. Experimental groups had a serum concentration of P4 preovulatory similar in every moment of evaluation. There wasn’t distinction of ACL and VCL between hormone treatments. However, the eCG group showed a tendency (P=0.08) to present higher DCL compared to the 2PGF and 2PGF+eCG groups. In addition to these findings, there was also a tendency (P=0.07) to higher concentrations of P4 on D24 of the protocol in the animals of the eCG group (11.00±3.32ng/mL) compared to the 2PGF group (6,37±1.31ng/mL), meanwhile the Control and 2PGF+eCG showed intermediate results that resembled both groups, with concentrations of 8.43±3.85 and 9.18±2.82ng/mL, respectively. Attempts to adjust proestrus were unable to improve follicular quality and minimize preovulatory luteal function, nor did they increase CL morphology and post-ovulatory luteal function, suggesting that in cyclic animals, FTAI protocols using a single PGF2&#945; dose and without the gonadotrophic support of eCG seems to promote adequate follicular and luteal responses.

Abstract in Portuguese:

RESUMO.- Rodrigues A.S., Silva M.A.A., Brandão T.O., Nascimento A.B., Bittencourt R.F., Chalhoub M., Bittencourt T.C.B.S.C. & Ribeiro Filho A.L. 2018. [Efficacy of the double PGF2 alpha dose-eCG association in proestrus of crossbred dairy cows submitted to IATF.] Eficácia da associação dupla dose PGF2 alfa-eCG no proestro de vacas leiteiras mestiças submetidas à IATF. Pesquisa Veterinária Brasileira 38(8):1518-1527. Centro Multidisciplinar Campus Barra, Universidade Federal do Oeste da Bahia, Avenida 23 de Agosto 860, Centro, Barra, BA 47100-000, Brazil. E-mail: alexandra.rodrigues@ufob.edu.br Objetivou-se avaliar o efeito de uma ou duas doses de prostaglandina F2&#945; (PGF2&#945;) associada ou não a gonadotrofina coriônica equina (eCG) sobre a dinâmica folicular, a função luteal pré-ovulatória, assim como as características morfofuncionais pós-ovulatórias do corpo lúteo (CL) em fêmeas mestiças cíclicas submetidas a um protocolo de inseminação artificial em tempo fixo (IATF). Para tanto, 29 vacas 3/4 Gir x Holandês multíparas foram submetidas ao exame de ultrassonografia (US) transretal e após a detecção do CL iniciou-se um protocolo de IATF em um dia denominado zero (D0), por meio da inserção do implante de progesterona (P4) associado à aplicação de 2,0mg de benzoato de estradiol. No D7 esses animais receberam 12,5mg de dinoprost trometamina. No D9 realizou a remoção dos dispositivos de P4 e aplicou 0,6mg de cipionato de estradiol. Nesse momento, as fêmeas foram subdivididas nos seguintes tratamentos: Grupo Controle (n=7), foi administrado 2,5mL de solução fisiológica; Grupo 2PGF (n=7), aplicou 12,5mg de dinoprost trometamina; Grupo eCG (n=7), administrou-se 300UI de eCG; Grupo 2PGF+eCG (n=8), realizou a aplicação de 300UI de eCG e 12,5mg de dinoprost trometamina. Para avaliar a dinâmica folicular foram realizados exames de US em modo B e power doppler (Mindray Z5, Shenzhen, China) a cada 12h do D7 até o momento da ovulação ou 96h após a remoção dos implantes de P4, mensurando-se o diâmetro folicular (DFOL), a área da parede folicular (AFOL) e a área de perfusão sanguínea da parede folicular (VFOL). Concomitante a cada exame, foram coletadas amostras de sangue sendo determinada a concentração sérica de P4 pré&#8209;ovulatória por meio da metodologia de quimioluminescência. No D24 foi realizada a US modo B e doppler analisando-se o diâmetro luteal (DCL), área luteal (ACL) e área de perfusão sanguínea do CL (VCL), assim como, foi coletada amostra de sangue para averiguar a concentração sérica de P4 pós-ovulatória. Os dados foram avaliados pelo Two-way ANOVA e análise de medidas repetidas considerando os efeitos do eCG, 2PGF e interação eCG*2PGF, P<0,05. Não houve diferença significativa entre os protocolos de sincronização para as variáveis DFOL, AFOL e VFOL ao longo do tempo da dinâmica folicular. Os grupos experimentais apresentaram uma concentração sérica de P4 pré-ovulatória semelhante em cada momento da avaliação. Não foi observada distinção da ACL e VCL entre os tratamentos hormonais, contudo o Grupo eCG demonstrou tendência (P=0,08) a apresentar maior DCL em relação ao Grupo 2PGF e 2PGF+eCG. Adicionalmente a estes achados, também foi constatado tendência (P=0,07) a maiores concentrações de progesterona no dia 24 do protocolo nos animais do Grupo eCG (11,00±3,32ng/mL) em relação ao Grupo 2PGF (6,37±1,31ng/mL), enquanto o Controle e 2PGF+eCG demonstraram resultados intermediários que se assemelham a ambos os grupos, com concentrações de 8,43±3,85 e 9,18±2,82ng/mL, respectivamente. As tentativas de ajustes no proestro foram incapazes de melhorar a qualidade folicular e minimizar a função luteal pré-ovulatória, assim como não incrementaram a morfologia do CL e a função luteal pós-ovulatória, sugerindo que em animais cíclicos mestiços protocolos de IATF com a utilização de uma única dose PGF2&#945; e sem o suporte gonadotrófico da eCG parece promover adequada resposta folicular e luteal.


#4 - Influence of body position on the measurement of electrocardiographic waves in healthy dogs

Abstract in English:

The agreement between the electrocardiographic waves measured from tracings recorded in right lateral recumbency and several other unusual body positions was assessed. Electrocardiograms were recorded in 160 healthy dogs in right lateral, left lateral, dorsal and sternal recumbencies, as well as in standing position. Considering the right lateral recordings as the gold standard, the lowest biases for the majority of ECG parameters were calculated from left lateral recordings, whereas the highest biases were documented from dorsal and standing positions. For the mean electrical axis, the dorsal recumbency produced the lowest bias, while the greatest one was identified in sternal position. An analysis of variance indicated differences when the means of P wave duration and amplitude, duration of QRS and QT, and mean electrical axis obtained in unusual positions were compared with right lateral. In conclusion, left lateral recumbency produced the most similar measurements as compared to right lateral, but the wide limits of agreement preclude the use and interpretation of these positions interchangeably.

Abstract in Portuguese:

A concordância entre a mensuração das ondas eletrocardiográficas a partir de traçados registrados em cães mantidos em decúbito lateral direito e em vários outros posicionamentos corporais foi avaliada nesta pesquisa. Para tanto, traçados eletrocardiográficos de 160 cães saudáveis foram registrados com os pacientes posicionados nos decúbitos lateral direito, lateral esquerdo, dorsal e esternal, assim como em posição quadrupedal. Tomando como padrão ouro os registros obtidos em decúbito lateral direito, as menores diferenças médias para a maioria dos parâmetros eletrocardiográficos foram obtidas a partir dos traçados registrados com o cão mantido em decúbito lateral esquerdo, enquanto as maiores diferenças médias foram documentadas nos registros obtidos nos decúbitos dorsal e quadrupedal. Para o eixo elétrico médio, o decúbito dorsal produziu a menor diferença média, enquanto a maior foi identificada no registro em posição esternal. A análise de variância mostrou diferenças entre as médias da duração e amplitude da onda P, duração do QRS e do intervalo QT e o eixo elétrico médico quando as posições não usuais foram comparadas com o decúbito lateral direito. Esta pesquisa mostrou que o decúbito lateral esquerdo produziu as medidas mais semelhantes quando comparado àquelas obtidas em decúbito lateral direito. No entanto, os limites de concordância amplos impedem que essas posições sejam utilizadas e interpretadas de maneira intercambiável.


#5 - Computerized electrocardiography in healthy conscious guinea pigs (Cavia porcellus), 36(12):1203-1208

Abstract in English:

ABSTRACT.- Botelho A.F.M., Oliveira M.S., Soto-Blanco B. & Melo M.M. 2016. Computerized electrocardiography in healthy conscious guinea pigs (Cavia porcellus). Pesquisa Veterinária Brasileira 36(12):1203-1208. Departamento de Clínica e Cirurgia Veterinárias, Escola de Veterinária, Universidade Federal de Minas Gerais, Av. Presidente Antônio Carlos 6627, Belo Horizonte, MG 31275-013, Brazil. E-mail: anaflaviamabo@gmail.com The purpose of this study is to evaluate healthy conscious guinea pigs as a model for electrophysiology assessment and to describe normal electrocardiographic patterns in controlled laboratory environment, establishing the best QT formula for this method. Electrocardiographic recordings of fifty adult conscious guinea pigs were obtained using a computerized electrocardiography. The electrocardiographic measurements of three different tracings were analyzed. The results obtained established normal mean and range values for the parameters: heart rate, waves and intervals of P-QRS-T deflections, as well as the mean cardiac axis. Groups were separated by body weight: group 1 gathered animals with 500-699g and group 2 with animals 700-900g. No differences were found when measurements were compared between groups, showing no significant difference between weight/body sizes to the electrocardiographic parameters (P<0.05). The mean corrected QT values (QTc) obtained using diverse formulae were significantly different (P<0.05), were the most consistent was Van der Water (QTcV). QTcV values were strongly correlated (r=98) and 95% confidence interval 185.7 to 195.2ms.Considering its simplicity and reliability, the QTcV was deemed the most appropriate to be used for the correction of QT interval in conscious guinea pigs.The results of this study also suggest that the values found can be used as reference for the species.

Abstract in Portuguese:

RESUMO.- Botelho A.F.M., Oliveira M.S., Soto-Blanco B. & Melo M.M. 2016. Computerized electrocardiography in healthy conscious guinea pigs (Cavia porcellus). [Eletrocardiografia computadorizada em cobaios (Cavia porcellus) saudáveis e conscientes.] Pesquisa Veterinária Brasileira 36(12):1203-1208. Departamento de Clínica e Cirurgia Veterinárias, Escola de Veterinária, Universidade Federal de Minas Gerais, Av. Presidente Antônio Carlos 6627, Belo Horizonte, MG 31275-013, Brazil. E-mail: anaflaviamabo@gmail.com O objetivo desse estudo foi avaliar cobaios hígidos e conscientes como modelos para estudos de eletrofisiologia e descrever os padrões eletrocardiográficos normais em ambiente laboratorial controlado, estabelecendo a melhor fórmula QT para esse método. Gravações eletrocardiográficas de cinquenta cobaios adultos conscientes foram obtidas usando eletrocardiografia computadorizada. As medidas eletrocardiográficas de três trechos diferentes foram analisadas. Os resultados estabeleceram média e desvio padrão para os parâmetros: frequência cardíaca, ondas e intervalos P-QRS-T, assim como o eixo cardíaco médio. Grupos foram separados de acordo com o peso: grupo 1 incluiu animais com 500-699g e o grupo 2 animais de 700-900g. Nenhuma diferença foi encontrada quando as medidas foram comparadas entre os grupos, mostrando que não há diferença significativa entre peso/tamanho corporal com os parâmetros eletrocardiográficos (p<0.05). As médias corrigidas dos valores do QT (QTc) obtidas usando diferentes fórmulas foram significativamente diferentes (p<0.05), sendo a mais consistente a de Van der Water (QTcV). Valores de QTcV fortemente correlacionam com o QT (r=98), com intervalo de confiança a 95% de 185.7 a 195.2 ms. Considerando a simplicidade e confiabilidade, o QTcV foi considerado apropriado para correção do intervalo QT em cobaios conscientes. Os resultados do presente estudo também sugerem que os valores encontrados possam ser utilizados como referência para essa espécie.


#6 - Electrocardiographic study of the Creole breed mares, 35(4):319-323

Abstract in English:

ABSTRACT.- Pascon J.P.E., Santos F.P., Pereira D.T.P., Mistieri M.L.A. & Mozzaquatro F.D. 2015. [Electrocardiographic study of the Creole breed mares.] Estudo eletrocardiográfico de éguas da raça Crioula. Pesquisa Veterinária Brasileira 35(4):319-323. Serviço de Cardiologia Veterinária, Curso de Medicina Veterinária, Universidade Federal do Pampa, Rodovia BR-472 Km 592, Uruguaiana, RS 97500-970, Brazil. E-mail: joaopascon@unipampa.edu.br The electrocardiography is an indispensable diagnostic tool to detect heart arrhythmias and electrical conductions disturbances in equines, as well as on prognosis determination of heart diseases, athletical performance, efficiency of training, and on electrolytic disturbance evaluation. However, electrocardiographic variables can be influenced by several factors such as age, gender, breed and phenotypic characteristics. Therefore the establishment of the characteristics of normality for different breed and phases of development is fundamental. Creole breed were firstly introduced to the American continent more than four centuries ago and it descends from horses of Iberian Peninsula. The breed is a result of natural selection that configured resistance and unique physical attributes. The present study aimed to analyze and compare the electrocardiographic parameters of Creole females in different ages, and verify the possibly influence of pregnancy on it. Digital electrocardiographic evaluation on apex-base lead was performed on 84 healthy creole mares (34 pregnant and 50 non-pregnant). The electrocardiograms were divided in groups concerning the age as G1 (until 4 years old), G2 (from 5 to 9 years old) and G3 (over 10 years old). No physiological or pathological heart arrhythmias and electrical conduction disturbances were seen in all examined mares. Sinus tachycardia , bifid P waves, rS configuration of QRS and biphasic T waves were the predominant patterns in all evaluated groups. Only the average of QRS duration of G1 females was significant superior (110,65±8,49) (p=0,0002) when compared with G2 (101,98±10,02) and G3 (100,92±10,72). The autonomic variables (ITV, average NN and SDNN) were lower in pregnant mares comparing to non-pregnant mares, suggesting a greater sympathetic autonomic system tonus and/or decrease of parasympathetic tonus on pregnant mares. In conclusion, the age affect only the QRS duration, and the pregnant condition was capable to decrease the time domain heart rate variability indexes with maybe influence the electrocardiographic evaluation of enrolled Creole mares.

Abstract in Portuguese:

RESUMO.- Pascon J.P.E., Santos F.P., Pereira D.T.P., Mistieri M.L.A. & Mozzaquatro F.D. 2015. [Electrocardiographic study of the Creole breed mares.] Estudo eletrocardiográfico de éguas da raça Crioula. Pesquisa Veterinária Brasileira 35(4):319-323. Serviço de Cardiologia Veterinária, Curso de Medicina Veterinária, Universidade Federal do Pampa, Rodovia BR-472 Km 592, Uruguaiana, RS 97500-970, Brazil. E-mail: joaopascon@unipampa.edu.br A eletrocardiografia constitui ferramenta indispensável no diagnóstico de arritmias e distúrbios de condução elétrica do coração de equinos, bem como na determinação do prognóstico de cardiopatias, do desempenho atlético, da eficiência do treinamento, além de sugerir distúrbios eletrolíticos. No entanto, as variáveis eletrocardiográficas em equinos podem sofrer influência de diversos fatores como a idade, sexo, raça e constituição morfofuncional, dentre outas, tornando-se necessário conhecer as características de normalidade para as diferentes raças e fases do desenvolvimento. Descendentes dos cavalos da Península Ibérica, a raça Crioula foi trazida ao continente americano há mais de quatro séculos, resultando em características físicas e de resistência únicas, dada por sua seleção natural. Desta forma, objetivou-se com o presente trabalho avaliar e comparar os aspectos eletrocardiográficos de fêmeas da raça Crioula, em diferentes idades, bem como avaliar possíveis alterações eletrocardiográficas secundárias a prenhes. Para tanto, 84 éguas hígidas (34 prenhes e 50 não prenhes) da raça Crioula foram submetidas à avaliação eletrocardiográfica digital na derivação ápice-base, e os registros eletrocardiográficos subdivididos quanto à idade em G1 (até 4 anos), G2 (5 a 9 anos), G3 (acima de 10 anos). Não foram observadas arritmias cardíacas fisiológicas ou patológicas e distúrbios de condução elétrica do coração nas 84 éguas. Houve predomino de taquicardia sinusal, ondas P bífidas, complexos QRS do tipo rS e ondas T bifásicas em todos os grupos. Apenas a duração média do complexo QRS foi superior no grupo G1 (110,65±8,49) quando comparadas aos grupos G2 (101,98±10,02) e G3 (100,92±10,72). As variáveis autonômicas mensuradas (ITV, NNmédio e SDNN) foram inferiores nas éguas prenhes em relação às não prenhes, sugerindo maior participação do sistema nervoso autônomo simpático e ou menor participação parassimpática. Conclui-se, portanto, que a idade influenciou apenas na duração do complexo QRS , e que a prenhes foi capaz de diminuir as variáveis de variabilidade da frequência cardíaca no domínio do tempo e, possivelmente, influenciar na avaliação eletrocardiográfica das éguas Crioulas aqui testadas.


#7 - Computerized electrocardiography in dogs: a comparative study, 33(7):949-953

Abstract in English:

ABSTRACT.- Oliveira L.S., Santos R.R.B., Melo M.B., Laranjeira D.F. & Barrouin-Melo S.M. 2013. [Computerized electrocardiography in dogs: a comparative study.] Eletrocardiografia computadorizada em cães: estudo comparativo. Pesquisa Veterinária Brasileira 33(7):949-953. Departamento de Anatomia, Patologia e Clínicas, Escola de Medicina Veterinária e Zootecnia, Universidade Federal da Bahia, Av. Adhemar de Barros 500, Salvador, BA 40170-110, Brazil. E-mail: barrouin@ufba.br Computerized electrocardiography (C-EKG) has been more frequently used in Veterinary Medicine. Many equipment models are available for this purpose. Due to possible device sensitivity and reproducibility differences during examination, the main goal of this study was to compare electrocardiographic parameters of dogs using two different C-EKG systems: Wincardio Micromed® (WIN) and TEB ECGPC® (TEB). Forty two healthy male and female dogs of different breeds (Cocker Spaniel, Dachshund, Labrador, Pinscher, Pitbull Terrier, Poodle, Schnauzer, Shih Tzu, Yorkshire and mongrel dogs), with age between 4 months and 16 years old were grouped according to weight and evaluated by both systems. The electrocardiographic measurements were performed on DII lead for both systems. The study showed that the TEB system was more sensitive for measurement of P wave and QRS complex duration, while the WIN system showed more sensitivity for the measurements of amplitude of the same parameters. The larger animals (26-37kg) showed greater variance in the measurements of P wave and QRS complex amplitude and duration than the groups of medium (14-25kg) or smaller (3-13kg) dogs. These differences must be considered when using diverse computerized electrocardiography systems to perform measurements due to the possibility of erratic interpretation of the results between veterinary medicine services.

Abstract in Portuguese:

RESUMO.- Oliveira L.S., Santos R.R.B., Melo M.B., Laranjeira D.F. & Barrouin-Melo S.M. 2013. [Computerized electrocardiography in dogs: a comparative study.] Eletrocardiografia computadorizada em cães: estudo comparativo. Pesquisa Veterinária Brasileira 33(7):949-953. Departamento de Anatomia, Patologia e Clínicas, Escola de Medicina Veterinária e Zootecnia, Universidade Federal da Bahia, Av. Adhemar de Barros 500, Salvador, BA 40170-110, Brazil. E-mail: barrouin@ufba.br O método de eletrocardiografia computadorizada (ECG-C) vem sendo crescentemente difundido na medicina veterinária, havendo atualmente diversas marcas e modelos de eletrocardiógrafos disponíveis no mercado. Diante da possibilidade de diferenças na sensibilidade e na reprodutibilidade das medidas obtidas nos traçados, o presente estudo teve como objetivo comparar os parâmetros eletrocardiográficos de cães, obtidos por dois sistemas. Foram avaliados dois diferentes softwares computadorizados, o Wincardio Micromed® (WIN) e o modelo TEB ECGPC® (TEB). Quarenta e dois cães hígidos, de diferentes raças (Cocker Spaniel, Daschund, Labrador, Pinscher, Pit Bull Terrier Poodle, Schnauzer, Shit Tzu, Yorkshire e sem raça definida), machos e fêmeas e com idade entre 4 meses e 16 anos foram agrupados segundo o peso e examinados pelos dois sistemas. As medidas eletrocardiográficas dos diferentes traçados foram analisadas na derivação DII. Os resultados indicaram que o sistema TEB apresentou maior sensibilidade na obtenção das medidas de duração da onda P e do complexo QRS, enquanto o sistema WIN foi mais sensível para determinar as medidas de amplitude dos mesmos parâmetros. Os animais de maior porte (26-37kg) apresentaram maior variância nas medidas de duração e amplitude de onda P e duração do complexo QRS em comparação aos cães de médio (14-25kg) e pequeno (1-13kg) porte. O achado de diferenças entre os sistemas testados deve ser levado em consideração ao se empregar os diversos equipamentos para diagnóstico por meio de ECG-C na rotina clínica, de modo a evitarem-se divergências na interpretação dos exames entre diferentes prestadores de serviços veterinários.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV