Resultado da pesquisa (4)

Termo utilizado na pesquisa modo-B

#1 - B-mode ultrasonography and gray scale histogram for evaluation of the nuchal ligament in Quarter horse

Abstract in English:

The gray scale histogram (GSH) makes it possible to measure the amount and distribution of gray shade frequencies, providing quantitative information on both echogenicity and echotexture of tissues. There is a need to diminish the subjectivity of the ultrasound images of the nuchal ligament (NL). This work proposes to evaluate the NL by ultrasound B-mode GSH images in different ages of Quarter horses. It used 15 healthy Quarter horses, which were classified by age into three different groups: “baby” (1), “sobreano” (2) and “adult” (3). The animals were submitted to chemical restraint for the ultrasound examination. Subsequently, the GSH tool was used in each image for statistical analysis. There was a significant difference between Mean and Mode between groups. Group 1 differed significantly when compared to Group 2 and 3. Group 2 presented superior echogenicity to Group 1 and 3. The height of the NL did not vary considerably between groups. GSH indicated that the echogenicity of NL in Quarter horses varies with age.

Abstract in Portuguese:

O histograma em escala de cinza (HEC) possibilita a mensuração da quantidade e distribuição da frequência de tonalidades de cinza, fornecendo informações quantitativas, tanto sobre a ecogenicidade quanto a ecotextura dos tecidos. Havendo a necessidade de diminuir a subjetividade das imagens ultrassonográficas do ligamento nucal (LN), esse trabalho propôs avaliar o LN por imagens ultrassonograficas modo-B pelo HEC em diferentes idades de cavalos da raça Quarto de Milha. Utilizou 15 cavalos da raça Quarto de Milha saudáveis os quais foram classificados por idade em três grupos diferentes: “baby” (1), “sobreano” (2) e “adulto” (3). Os animais foram submetidos a contenção química para a realização do exame ultrassonográfico. Posteriormente, a ferramenta HEC foi empregada em cada imagem para análise estatística. Houve diferença significativa entre as variáveis “Mean” e “Mode” entre os grupos. O Grupo 1 diferenciou significativamente quando comparado ao Grupo 2 e 3. O Grupo 2 apresentou ecogenicidade superior ao Grupo 1 e 3. Quanto à altura do LN não teve variação considerável entre os grupos. O HEC indicou que a ecogenicidade do LN em cavalos Quarto de Milha varia conforme a idade.


#2 - B-mode and Doppler ultrasonography in the assessment of the common carotid arteries of equines and mules and the relation with body mass, age and neck circumference

Abstract in English:

As age increases, changes in cardiovascular anatomy and physiology occur, even in the absence of disease. Thus, studies of vessel hemodynamics are considered primordial to detect any cardiovascular changes. The objective of this study has been to describe the parameters of B-mode and spectral Doppler ultrasonography in the evaluation of the common carotid arteries of 11 equine and 11 mules, and correlate with age, body mass and neck circumferences. The diameters, intima - media thickness (IMT), resistivity index (RI), pulsatility index (PI), systolic velocity (SV), diastolic velocity (DV), maximum velocity (MV), vascular flow index (VFI), body mass, age, circumference and neck length. Ultrasonographic variables were evaluated in three different region called cranial, middle and caudal. Equine females presented higher values regarding the body mass, age and neck length, as compared to the neck circumferences of the animals, those of the mules were superior. The age of the mules had a positive correlation with the body mass, diameter and neck circumferences, it has a negative correlation between age and vessel diameters. The body mass of the mules had a positive correlation with age and vessel diameters, and with vessel diameters and neck circumferences in equine females. The RI and PI variables had a positive correlation with body mass for mules, and with age for equine females. The DV had a negative correlation with body mass for both equine and mule females. Regarding the variables MV and VFI, age correlated negatively for mules, while it was not significant for equine females. It found a difference between equine females and mules in the correlations performed, with body mass, age, neck circumferences and between B-mode and Doppler ultrasonography variables.

Abstract in Portuguese:

Com o aumento da idade ocorrem alterações na anatomia e fisiologia cardiovascular, mesmo na ausência de doenças. Assim, os estudos da hemodinâmica dos vasos são considerados primordiais para detectar quaisquer alterações cardiovasculares. Esse trabalho tem como objetivo descrever as variáveis de ultrassonografia modo-B e Doppler espectral na avaliação das artérias carótidas comuns de 11 fêmeas equinas e 11 muares, e correlacionar com idade, massa corpórea e circunferências dos pescoços. Para tais procedimentos foram avaliados os diâmetros, espessura da camada íntima média (EIM), índice de resistividade (IR), índice de pulsatilidade (IP), velocidade sistólica (VS), velocidade diastólica (VD), velocidade máxima (VM), índice de vascularização de fluxo (IVF), massa corpórea, idade, circunferências e comprimentos dos pescoços. As variáveis ultrassonográficas foram avaliadas em três regiões diferentes denominados de crania médio e caudal. As fêmeas equinas apresentaram valores maiores referente ao massa corpórea, idade e comprimento dos pescoços, já em relação às circunferências dos pescoços dos animais, as dos muares foram superiores. A idade dos muares possuiu correlação positiva com a massa corpórea, diâmetro e com as circunferências dos pescoços, com as fêmeas equinas, possui correlação negativa entre idade e os diâmetros dos vasos. A massa corpórea dos muares teve correlação positiva com idade e diâmetros dos vasos, já às fêmeas equinas com diâmetros dos vasos e as circunferências dos pescoços. As variáveis IR e IP tiveram correlação positiva com a massa corpórea para os muares, e com idade para fêmeas equinas. O VD teve correlação negativa com a massa corpórea tanto para as fêmeas equinas quanto nos muares. Já as variáveis VM e IVF, a idade correlacionou negativamente para os muares, enquanto não foi significativo para as fêmeas equinas. Averiguou diferença entre fêmeas equinas e muares nas correlações realizadas, com a massa corpórea, idade, circunferências dos pescoços e entre as variáveis da ultrassonografia modo-B e Doppler.


#3 - Biometric, B-mode and color Doppler ultrasound assessment of eyes in healthy dogs

Abstract in English:

B-scan ultrasonography is an important diagnostic tool that allows characterization of internal organ anatomy and, when complemented by Doppler ultrasound, allows vascular hemodynamic assessment, increasing the diagnostic accuracy. Thus, the aim of the present study was the B-scan ultrasound characterization and measurement of the eyeball segments and assessment of the external ophthalmic artery by color and pulsed Doppler. Sixty eyeballs were assessed from 30 dogs of different breeds using an 8.5MHz microconvex transductor. First, biometry was performed by B-scan of the following segments: axial length (M1), anterior chamber depth (M2), lens thickness (M3), lens length (M4), vitreous chamber depth (M5), optical disc length (M6) and optic nerve diameter (M7). Colored Doppler identified the external ophthalmic article and pulsed Doppler assessed its flow, and the following were measured: systolic peak velocity (VPS), final diastolic velocity (VDF), resistivity index (IR) and pulse index (IP). No statistical difference was observed for the biometric values of the eye segments between the right and left eyes (p>0.05). The vitreous chamber depth (M5) was shown to be the biometric variable with greatest bilateral symmetry, varying from 0.79 to 0.87cm and 0.78 to 0.86cm for the right and left eye, respectively. The ophthalmic artery was visualized over the optic nerve towards the eyeball, with flow stained red. There was no significant statistical difference between the Doppler velocimetric values for the ophthalmic artery between the right and left eye of the animals assessed (p>0.05). The mean resistivity index (RI) showed average values equal to 0.63±0.03, bilaterally. The mean base velocity was 17.50cm/s and 18.18cm/s at the systolic peak and 6.21cm/s and 6.68cm/s at the end of the diastole, for the right and left eyes respectively. The anatomic, biometric and hemodynamic characterization using the ultrasound B-scan and the Doppler modalities permitted the ultrasonographic and Doppler velocimetric assessment of the eyeball components in dogs of different breeds, and it can be used in ophthalmic clinical routine to identify eye pathologies.

Abstract in Portuguese:

O exame ultrassonográfico modo-B é uma importante ferramenta diagnóstica que permite caracterizar a anatomia interna dos órgãos e, complementada pelo exame modo Doppler, possibilita realizar a avaliação hemodinâmica vascular, aumentando a acurácia diagnóstica. Desta forma, este trabalho teve como objetivo a caracterização ultrassonográfica e mensuração dos segmentos do bulbo ocular modo-B, assim como a avaliação da artéria oftálmica externa pelo Doppler colorido e pulsado. Foram avaliados 60 bulbos oculares de 30 cães de diferentes raças utilizando transdutor microconvexo de 8,5MHz. Inicialmente foi realizada biometria por meio do exame em modo-B dos seguintes seguimentos: comprimento axial (M1), profundidade da câmara anterior (M2), espessura da lente (M3), comprimento da lente (M4), profundidade da câmara vítrea (M5), comprimento do disco óptico (M6) e diâmetro do nervo óptico (M7). A artéria oftálmica externa foi identificada pelo Doppler colorido e seu fluxo foi avaliado por meio do Doppler pulsado, sendo mensurados: velocidade do pico sistólico (VPS), velocidade diastólica final (VDF), índice de resistividade (IR) e índice de pulsatilidade (IP). Não foi verificada diferença estatística para os valores biométricos dos seguimentos oculares entre os olhos direito e esquerdo (p>0,05). A profundidade da câmera vítrea (M5), mostrou-se a variável biométrica com maior simetria bilateral, variando entre 0,79 a 0,87cm e 0,78 a 0,86cm para o olho direito e esquerdo, respectivamente. A artéria oftálmica foi visibilizada sobre o nervo óptico em direção ao bulbo ocular, com fluxo marcado em vermelho. Não houve diferença estatística significativa entre os valores Dopplervelocimétricos da artéria oftálmica entre do olho direito e esquerdo dos animais avaliados (p>0.05). O índice de resistividade (IR) médio evidenciou valores médios sendo igual a 0,63±0,03, bilateralmente. A velocidade basal média foi 17,50cm/s e 18,18cm/s no pico sistólico e 6,21cm/s e 6,68cm/s no final da diástole, para os olhos direito e esquerdo, respectivamente. A caracterização anatômica, biométrica e hemodinâmica utilizando o exame ultrassonográfico modo-B e as modalidades do Doppler permitiram a avaliação ultrassonográfica e Dopplervelocimétrica dos componentes do bulbo ocular nos cães de diferentes raças, podendo ser utilizados na rotina clínica oftalmológica para identificação de patologias oculares.


#4 - B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age, 36(6):545-550

Abstract in English:

ABSTRACT.- Santarosa B.P., Ferreira D.O.L., Belotta A.F., Dias A., Mamprim M.J. & Gonçalves R.C. 2016. B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age. Pesquisa Veterinária Brasileira 36(6):545-550. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus Botucatu, Distrito de Rubião Junior s/n, Botucatu, SP 18618-970, Brazil. E-mail: biancasantarosavet@gmail.com There is no standardization in the literature of kidney length in sheep at different ages, as there are few studies about the access with the Doppler triplex ultrasound for the renal vascularization in this species. Eighty healthy sheep of three age groups of Ile de France and White Dorper breed were used: 20 lambs, 30 yearlings and 30 adults (8 rams and 22 ewes). Renal healthiness of the animals was confirmed by serum biochemical tests of urea and creatinine, and by observation of renal architecture with conventional ultrasound, besides measurement of vital parameters. A portable ultrasound (My LabTM30 Vet Gold Esaote®, Esaote Healthcare) device was used, with a convex transducer with 3.5MHz frequency. After identification of the kidneys in two-dimensional mode, the measurement of length in the sagittal section was performed in all sheep (n=80). Then color Doppler was activated for visualization of renal and interlobar arteries of the right kidney, and the resistivity index (RI) of the yearlings (n=30) and ewes (n=22) was measured. Biochemical tests remained within normal limits and renal architecture was preserved. The values &#8203;&#8203;of the right and left renal length were different between the groups, increasing with age (4.34cm and 4.31cm in lambs; 6.08cm and 6.23cm in yearlings; 7.57cm and 7.37cm in adults, respectively). Median values of RI of the renal artery were statistically different (p<0.05) between the groups of yearlings (0.57) and ewes (0.52). The median RI of the interlobar artery was similar in yearlings (0.58) and ewes (0.54).

Abstract in Portuguese:

RESUMO.- Santarosa B.P., Ferreira D.O.L., Belotta A.F., Dias A., Mamprim M.J. & Gonçalves R.C. 2016. B-Mode and pulsed Doppler sonography of kidney in healthy sheep according to age. [Ultrassonografia Modo-B e Doppler pulsado dos rins de ovinos hígidos de acordo com a idade.] Pesquisa Veterinária Brasileira 36(6):545-550. Departamento de Clínica Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus Botucatu, Distrito de Rubião Junior s/n, Botucatu, SP 18618-970, Brazil. E-mail: biancasantarosavet@gmail.com Não há na literatura padronização do comprimento renal de ovinos, em diferentes idades, assim como existem poucos trabalhos sobre a vascularização renal nesta espécie. Utilizaram-se no total 80 ovinos hígidos de três faixas etárias, das raças Ile de France e White Dorper: 20 cordeiros, 30 borregos e 30 adultos (8 carneiros e 22 ovelhas). A higidez renal dos animais foi comprovada por exames bioquímicos séricos de ureia e creatinina e pela observação da arquitetura renal. Utilizou-se aparelho de Ultrassom portátil (My LabTM30 Vet Gold Esaote®, Esaote Healthcare), com transdutor convexo de frequência de 3,5MHz. Após identificação dos rins no modo bidimensional, foi realizada a mensuração do comprimento no corte sagital em todos os ovinos. Em seguida, Doppler colorido foi ativado para visualização das artérias renal e interlobar do rim direito, e mensurou-se o índice de resistividade dos borregos (n=30) e ovelhas (n=22). Os exames bioquímicos permaneceram dentro da normalidade e a arquitetura renal estava preservada. Os valores do comprimento renal direito e esquerdo foram diferentes entre os grupos, sendo crescente conforme a idade (4,34 e 4,31 em cordeiros, 6,08 e 6,23 em borregos, 7,57 e 7,37 em adultos). As medianas do IR da artéria renal foi estatisticamente diferente (p<0,05) entre os grupos dos borregos (0,57) e ovelhas (0,52). A mediana do IR da artéria interlobar não apresentou diferença entre borregos (0,58) e ovelhas (0,54).


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV