Resultado da pesquisa (3)

Termo utilizado na pesquisa tonometry

#1 - Macroscopic morphological aspects, ecometry and rebound tonometry of the eye bulb in sloth (Bradypus variegatus)

Abstract in English:

The field related to the visual system of wild animals is deeply scarce. Settling anatomical and physiological parameters for these animals is still a descriptive vision for Bradypus variegatus (Schinz, 1825). Thus, our research aimed to determine patterns of normal eye for this species. For this purpose, eight eye bulbs were dissected from the carcasses obtained by natural death, and then performed an overview of ocular anatomical. Rebound tonometry (RBT) and ocular B-mode ultrasonography were also applied for eight eyes in four animals from “Parque Estadual Dois Irmãos”, situated in the city of Recife, state of Pernambuco (PE), to estimate the intraocular pressure and ocular ecobiometry. The ocular morphology of sloth is similar as described for other species, however, with some peculiarities. They present a third eyelid emerging in the nasal region of the inferior conjunctival sac and retina and also contain little differentiated blood vessels. Medium the intraocular pressure (IOP) was 4.25mmHg with no difference for both eyes. Ultrasonography of ocular anatomy is also similar regarding other species. Ecobiometric patterns were evaluated to determine the anterior chamber depth, lens width, vitreous chamber depth, and axial length (AL) of ocular globe and the averaged as shown 0.63±1.11mm, 3.73±0.24mm, 6.15±0.41mm, 3.70±0.27mm, and 8.48±0.22mm, respectively. There was no difference between the right and left eyes. The RBT and ocular B-mode ultrasonography are fast exams and easy for animal testing. This study contributed to the characterization of ocular anatomy as well as settling medium values of IOP and intraocular measures; however, further research on physiology and histology is necessary to better understand the visual function of the species.

Abstract in Portuguese:

O campo de estudo relacionado ao sistema visual de animais silvestres é muito escasso. Estabelecer parâmetros anatômicos e fisiológicos para estes animais ainda está restrito a uma visão descritiva, assim ocorre em Bradypus variegatus (Schinz, 1825). Diante deste fato, objetivou-se com este estudo determinar padrões de normalidade oftálmica nesta espécie. Para isto foram dissecados oito bulbos oculares de cadáveres obtidos por morte natural e realizada a descrição anatômica ocular. Além disso, foram realizadas tonometria de rebote (TonoVet®) e ultrassonografia em modo B em oito olhos de quatro animais provenientes do Parque Estadual Dois Irmãos, Recife/PE, para avaliação da pressão intraocular e realização da ecobiometria ocular. A anatomia ocular do bicho-preguiça é semelhante à descrita para outras espécies com algumas particularidades. Apresentam uma terceira pálpebra emergindo na região nasal do saco conjuntival inferior e retina com vasos sanguíneos pouco diferenciados. A pressão intraocular média foi de 4,25mmHg não havendo diferença entre os olhos direito e esquerdo. A anatomia ocular ultrassonográfica é semelhante à encontrada para outras espécies. Os padrões ecobiométricos obtidos foram: profundidade da câmara anterior, espessura do cristalino, diâmetro do cristalino, profundidade da câmara vítrea e comprimento axial do bubo ocular com tamanhos médios de 0,63±1,11mm, 3,73±0,24mm, 6,15±0,41mm, 3,70±0,27mm e 8,48±0,22mm, respectivamente. Não houve diferença entre os olhos direito e esquerdo. A tonometria de rebote e a ultrassonografia ocular em modo B são exames de rápida e fácil execução, sendo bem tolerados pelos animais. Este estudo contribuiu para a caracterização anatômica ocular e para o estabelecimento de valores médios da pressão intraocular e das medidas intraoculares, no entanto são necessárias outras pesquisas na área da fisiologia e histologia para melhor compreensão da função visual da espécie.


#2 - Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva), 37(8):871-873

Abstract in English:

ABSTRACT.- Falcão M.S.A., Monteiro R.V., Oriá A.P. & Galera P.D. 2017. Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva). Pesquisa Veterinária Brasileira 37(8):871-873. Departamento de Cirurgia de Pequenos Animais, Faculdade de Agronomia e Medicina Veterinária, Universidade de Brasília, Campus Universitário Darcy Ribeiro, Avenida L4 Norte, Asa Norte, Brasília, DF 70910-900, Brazil. E-mail: dra.paulagalera@gmail.com The aim of this study was to describe the modified Schirmer tear test (mSTT), intraocular pressure (IOP) by rebound tonometry and palpebral fissure length (PFL) in blue-fronted Amazon parrots (Amazona aestiva). Thirty-five healthy adult animals from a conservation breeding center in Brazil were used in this study. Modified Schirmer tear test, rebound tonometry and PFL measurements were performed in both eyes, with birds under physical restraint. Mean mSTT was 6.2±0.1mm/min and mean IOP was 6.4±0.1mmHg, while PFL was 10.1±0.1mm. A moderate correlation was seen between mSTT and PFL for OD (ρ=0.14) and OS (ρ=0.20). The results provide ophthalmic tests reference values for A. aestiva.

Abstract in Portuguese:

RESUMO.- Falcão M.S.A., Monteiro R.V., Oriá A.P. & Galera P.D. 2017. Modified Schirmer tear test and rebound tonometry in blue-fronted Amazon parrot (Amazona aestiva). [Teste lacrimal de Schirmer modificado e tonometria de rebote em papagaio-verdadeiro (Amazona aestiva).] Pesquisa Veterinária Brasileira 37(8):871-873. Departamento de Cirurgia de Pequenos Animais, Faculdade de Agronomia e Medicina Veterinária, Universidade de Brasília, Campus Universitário Darcy Ribeiro, Avenida L4 Norte, Asa Norte, Brasília, DF 70910-900, Brazil. E-mail: dra.paulagalera@gmail.com O objetivo deste estudo foi descrever o teste lacrimal de Schirmer modificado (TLSm), a pressão intraocular (PIO) pela tonometria de rebote e o comprimento da fissura palpebral (FP) do papagaio-verdadeiro (Amazona aestiva). Foram avaliados 35 papagaios adultos e saudáveis, provenientes de um Criadouro Conservacionista do Brasil. Após avaliação clínica e laboratorial, as aves foram fisicamente contidas para aferição, em ambos os olhos, do TLSm, da PIO pela tonometria de rebote e do comprimento da FP utilizando-se um paquímetro digital. Valor médio do TLSm foi 6.2±0.1mm/min e da PIO foi 6.4±0.1 mmHg, enquanto a aferição da FP foi 10.1±0.1mm. Uma correlação moderada foi observada entre TLSm e a FP para olho direito (OD) (ρ=0.14) e olho esquerdo (OE) (ρ=0.20). Os resultados podem servir como valores de referência para testes oftálmicos para A. aestiva.


#3 - Intraocular pressure and Schirmer tear test values in maned wolf (Chrysocyon brachyurus), 36(9):919-923

Abstract in English:

ABSTRACT.- Honsho C.S., Jorge A.T., Oliveira L.T., Paulino-Junior D., Mattos-Junior E., Nishimura L.T. & Dias W.O. 2016. Intraocular pressure and Schirmer tear test values in maned wolf (Chrysocyon brachyurus). Pesquisa Veterinária Brasileira 36(9):919-923. Curso de Pós-Graduação de Medicina Veterinária, University of Franca, Parque Universitário, Avenida Dr. Armando Salles Oliveira 201, Franca, SP 14404-600, Brazil. E-mail: cristiane.honsho@unifran.edu.br The purpose of this study was to establish baseline data on lacrimal quantity (STT-1) and intraocular pressure (IOP) in captive maned wolves. Ten healthy adult maned wolves were contained with a snare pole and muzzle and kept in decubitus of the left side. STT-1 measurement was performed on the lateral third of the lower conjunctival sac for one minute. The cornea was desensitized and intraocular pressure was measured with an tonopen. Average STT-1 in both eyes was 11±5mm.min-1, with no statistical difference between the left and right eye (p=0.960). Average IOP in both eyes was 20±6mmHg, with no statistical difference between the left and right eye (p=0.836). Average STT-1 was lower than, and IOP was the same as normal levels found in dogs. There was no statistical difference in the age of the animals, and STT-1 and IOP values. In the present paper, average maned wolf STT-1 levels were lower compared with those found in dogs, while the IOP was the same in maned wolves as in dogs. Due to the increased incidence in providing emergency care for maned wolf victims of road kill and fires, determination reference values of ocular parameters may improve the correct diagnosis and treatment of the disease.

Abstract in Portuguese:

RESUMO.- Honsho C.S., Jorge A.T., Oliveira L.T., Paulino-Junior D., Mattos-Junior E., Nishimura L.T. & Dias W.O. 2016. Intraocular pressure and Schirmer tear test values in maned wolf (Chrysocyon brachyurus). [Pressão intraocular e teste lacrimal de Schirmer em lobos-guará (Chrysocyon brachyurus).] Pesquisa Veterinária Brasileira 36(9):919-923. Curso de Pós-Graduação de Medicina Veterinária, University of Franca, Parque Universitário, Avenida Dr. Armando Salles Oliveira 201, Franca, SP 14404-600, Brazil. E-mail: cristiane.honsho@unifran.edu.br O objetivo deste estudo foi estabelecer dados de referência sobre a produção lacrimal (STT-1) e pressão intraocular (PIO) em lobos-guará em cativeiro. Foram utilizados 10 lobos-guará, saudáveis e adultos. Os animais foram contidos com cambão e mordaça e mantidos em decúbito lateral esquerdo. O TLS foi realizado no terço médio da pálpebra inferior, durante um minuto. A córnea foi dessensibilizada e a PIO mensurada com tonopen. A média do TLS-1 dos olhos direitos e esquerdo foi 11±5mm/min, não havendo diferença significativa entre os olhos (p=0,960). A média da PIO dos olhos direitos e esquerdo foi 20±6mmHg, não observando diferença entre os olhos direitos e esquerdos (p=0,836). Média STT-1 foi menor do que, e PIO foi o mesmo que os níveis normais em cães. Não houve diferença estatística na idade dos animais e valores STT-1 e da PIO. No presente trabalho, os níveis médios de guará STT-1 foram mais baixos em comparação com as observadas nos cães, enquanto que a pressão intraocular foi a mesma nos lobos guará como em cães. Devido ao aumento da incidência na prestação de cuidados de emergência para vítimas de lobos-guará atropelamentos e incêndios, determinar os valores de referência dos parâmetros oculares podem melhorar o diagnóstico correto e tratamento de doenças.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV