Resultado da pesquisa (6)

Termo utilizado na pesquisa measurement

#1 - Measuring of the salivary immunoglobulin in Callithrix jacchus primates in captivity running title: salivary immunoglobulin in marmoset

Abstract in English:

The primary antibody in the mucous membranes and exocrine glands is a polymetric secretory immunoglobulin A. This immunoglobulin has been used as an indicator of stress in various animals, including nonhuman primates, and can also be used to monitor immune activity. The secretory immunoglobulin A is predominantly found in seromucous secretions such as saliva, tears, colostrum, milk, and liquor, as well as tracheobronchial, intestinal, and genitourinary secretions. This study aimed to measure the salivary IgA levels in Callithrix jacchus (common marmoset) by the enzyme-linked immunosorbent assay test (ELISA). Twelve pairs of animals were used, previously conditioned by the operant conditioning technique with positive reinforcement to saliva collection. Samples were collected once a week for six months. In this experiment, the salivary secretory immunoglobulin A concentrations in Callithrix jacchus were very low. We suggest new studies using other techniques to quantify the IgA quantities in the saliva of these animals.

Abstract in Portuguese:

O principal anticorpo presente nas mucosas e glândulas exócrinas é uma IgA polimétrica denominada sIgA. Esta imunoglobulina vem sendo utilizada como indicadora de estresse em diversos animais incluindo primatas não humanos, podendo também ser utilizada para o monitoramento da atividade imunológica. A imunoglobulina A secretora é encontrada predominantemente em secreções seromucosas, como saliva, lágrimas, colostro, leite, liquor, bem como secreções traqueobrônquicas, intestinais e geniturinárias. O objetivo deste estudo foi mensurar os níveis da IgA salivar em Callithrix jacchus (sagui comum) através do teste de imunoabsorção enzimática (ELISA). Doze pares de animais foram previamente condicionados pela técnica de condicionamento operante com reforço positivo à coleta de saliva. As amostras foram coletadas uma vez por semana por seis meses. Neste experimento as concentrações de imunoglobulina salivar A secretora em Callithrix jacchus foram muito baixas. Nós sugerimos novos estudos utilizando outras técnicas para quantificar a IgA na saliva desses animais.


#2 - Influence of body position on the measurement of electrocardiographic waves in healthy dogs

Abstract in English:

The agreement between the electrocardiographic waves measured from tracings recorded in right lateral recumbency and several other unusual body positions was assessed. Electrocardiograms were recorded in 160 healthy dogs in right lateral, left lateral, dorsal and sternal recumbencies, as well as in standing position. Considering the right lateral recordings as the gold standard, the lowest biases for the majority of ECG parameters were calculated from left lateral recordings, whereas the highest biases were documented from dorsal and standing positions. For the mean electrical axis, the dorsal recumbency produced the lowest bias, while the greatest one was identified in sternal position. An analysis of variance indicated differences when the means of P wave duration and amplitude, duration of QRS and QT, and mean electrical axis obtained in unusual positions were compared with right lateral. In conclusion, left lateral recumbency produced the most similar measurements as compared to right lateral, but the wide limits of agreement preclude the use and interpretation of these positions interchangeably.

Abstract in Portuguese:

A concordância entre a mensuração das ondas eletrocardiográficas a partir de traçados registrados em cães mantidos em decúbito lateral direito e em vários outros posicionamentos corporais foi avaliada nesta pesquisa. Para tanto, traçados eletrocardiográficos de 160 cães saudáveis foram registrados com os pacientes posicionados nos decúbitos lateral direito, lateral esquerdo, dorsal e esternal, assim como em posição quadrupedal. Tomando como padrão ouro os registros obtidos em decúbito lateral direito, as menores diferenças médias para a maioria dos parâmetros eletrocardiográficos foram obtidas a partir dos traçados registrados com o cão mantido em decúbito lateral esquerdo, enquanto as maiores diferenças médias foram documentadas nos registros obtidos nos decúbitos dorsal e quadrupedal. Para o eixo elétrico médio, o decúbito dorsal produziu a menor diferença média, enquanto a maior foi identificada no registro em posição esternal. A análise de variância mostrou diferenças entre as médias da duração e amplitude da onda P, duração do QRS e do intervalo QT e o eixo elétrico médico quando as posições não usuais foram comparadas com o decúbito lateral direito. Esta pesquisa mostrou que o decúbito lateral esquerdo produziu as medidas mais semelhantes quando comparado àquelas obtidas em decúbito lateral direito. No entanto, os limites de concordância amplos impedem que essas posições sejam utilizadas e interpretadas de maneira intercambiável.


#3 - Radiographic measurements related with the cardiac size in young female Bergamasca sheep, 37(12):1526-1530

Abstract in English:

ABSTRACT.- Babicsak V.R., Alves L.S., Tsunemi M.H. & Vulcano L.C. 2017. Radiographic measurements related with the cardiac size in young female Bergamasca sheep. Pesquisa Veterinária Brasileira 37(12):1526-1530. Departamento de Reprodução Animal e Radiologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus de Botucatu, Rua Prof. Doutor Walter Mauricio Correa s/n, Botucatu, SP 18618-681, Brazil. E-mail: viviam.babicsak@gmail.com In thoracic radiographic examination, routinely used in cases which cardiac evaluation is indicated, quantitative assessment of the heart is a useful role to be used in combination with subjective analysis. Numerous studies about objective assessment of the cardiac size have been performed in several species, including sheep; however, there is scarce information regarding cardiac parameters of young Bergamasca sheep. Therefore, the purpose of this study was to determine the average results and suggest the range of expected normal values for parameters related to the heart size of young female Bergamasca sheep by radiographic evaluation. Fifteen healty 8 months-old female Bergamasca sheep (mean weight: 41.13±4.71kg) were submitted to right lateral recumbency thoracic radiography. The length of the fourth and third to fifth thoracic vertebrae, cardiac height and width, vertebral heart size, cardiophrenic contact, caudal vena cava height, aorta caliber and tracheal angle were measured and the mean results found were, respectively: 2.46±0.11cm (95% CI 2.41-2.52), 7.53±0.30cm (95% CI 7.38-7.68), 13.83±0.57cm, (95% CI 13.54-14.12), 8.99±0.37cm (8.80-9.17), 8.99±0.27 vertebrae (95% 8.85-9.13), 4.55±0.70cm (95% CI 4.19-4.90), 1.88±0.19cm (95% CI 1.79-1.97), 2.05±0.11cm (95% CI 2.00-2.11) and 14.36±2.73° (95% CI 12.98-15.75). Cardiac height and width and the sum of these parameters were compared to the length of third to fifth thoracic vertebrae, resulting in the respective mean values: 1.84±0.08 (95% IC 1.80-1.88), 1.20±0.05 (1.17-1.22) and 3.04±0.11 (95% IC 2.98-3.09). Ratios of cardiophrenic contact to cardiac height and caudal vena cava height to length of fourth thoracic vertebra were also evaluated and the mean values obtained were 0.33±0.05 (95% IC 0.30-0.35) and 0.76±0.08 (95% IC 0.72-0.81), respectively. Authors suggest that the values available in this study may be used as reference for normal heart size in young female Bergamasca sheep and as basis for further studies.

Abstract in Portuguese:

RESUMO.- Babicsak V.R., Alves L.S., Tsunemi M.H. & Vulcano L.C. 2017. Radiographic measurements related with the cardiac size in young female Bergamasca sheep. [Mensurações radiográficas relacionadas às dimensões cardíacas em borregas Bergamácia.] Pesquisa Veterinária Brasileira 37(12):1526-1530. Departamento de Reprodução Animal e Radiologia Veterinária, Faculdade de Medicina Veterinária e Zootecnia, Universidade Estadual Paulista, Campus de Botucatu, Rua Prof. Doutor Walter Mauricio Correa s/n, Botucatu, SP 18618-681, Brazil. E-mail: viviam.babicsak@gmail.com No exame radiográfico torácico, rotineiramente utilizado em casos em que a avaliação cardíaca é indicada, a análise quantitativa do coração é um recurso útil a ser usado em combinação com a avaliação subjetiva. Diversos estudos relacionados à análise objetiva do tamanho cardíaco têm sido realizados em várias espécies, incluindo ovinos; no entanto, há pouca informação sobre os parâmetros cardíacos de ovinos jovens da raça Bergamácia. Dessa forma, o objetivo deste estudo foi determinar as médias e sugerir o intervalo de valores esperados para os parâmetros relacionados ao tamanho cardíaco de borregas Bergamácia por meio da avaliação radiográfica. Quinze borregas Bergamácia de 8 meses de idade (média de peso: 41,13±4,71kg) foram submetidas à radiografia torácica em decúbito lateral direito. O comprimento do quarto e da terceira a quinta vértebras torácicas, a altura e a largura cardíaca, o tamanho do coração em relação à unidade de vértebra torácica, o contato cardiofrênico, a altura da veia cava caudal, o calibre da aorta e o ângulo traqueal foram mensurados, sendo encontrados os seguintes valores médios, respectivamente: 2,46±0,11cm (95% IC 2,41-2,52), 7,53±0,30cm (95% IC 7,38-7,68), 13,83±0,57cm, (95% IC 13,54-14,12), 8,99±0,37cm (95% IC 8,80-9,17), 8,99±0,27 vértebras (95% IC 8,85-9,13), 4,55±0,70cm (95% IC 4,19-4,90), 1,88±0,19cm (95% IC 1,79-1,97), 2,05±0,11cm (95% IC 2,00-2,11) e 14,36±2,73° (95% IC 12,98-15,75). A altura e a largura cardíaca e a soma desses parâmetros foram comparados com o comprimento da terceira a quinta vértebras torácicas, resultando nos respectivos valores médios: 1,84±0,08 (95% IC 1,80-1,88), 1,20±0,05 (1,17-1,22) e 3,04±0,11 (95% IC 2,98-3,09). Também foram avaliadas as relações entre o contato cardiofrênico e a altura cardíaca e entre a altura da veia cava caudal e o comprimento da quarta vértebra torácica, sendo determinados os valores médios de 0,33±0,05 (95% IC 0,30-0,35) e 0,76±0,08 (95% IC 0,72-0,81), respectivamente. Os autores sugerem que os valores disponíveis no presente estudo podem ser utilizados como referência na avaliação das dimensões cardíacas de borregas Bergamácia e como base para estudos futuros.


#4 - Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm, 37(12):1545-1553

Abstract in English:

ABSTRACT.- Maioli M.A. & Nogueira G.P. 2017. [Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm.] Padronização da quantificação do fator de crescimento semelhante a insulina I (IGF-I) em plasma bovino por ELISA. Pesquisa Veterinária Brasileira 37(12):1545-1553. Departamento de Apoio a Produção e Saúde Animal, Faculdade de Medicina Veterinária de Araçatuba, Universidade Estadual Paulista, Unesp-Araçatuba, Rua Clóvis Pestana 793, Araçatuba, SP 16050-680, Brazil. E-mail: maioli_marcos@hotmail.com This study aimed to standardize an in house competitive enzyme-linked immunosorbent assay (cELISA) to determine plasma concentrations of total insulin-like growth factor I (IGF-I) for the bovine specie using the amplification biotin-streptavidin peroxidase system. The IGF-I was extracted from insulin-like growth factor binding proteins (IGFBPs) using the acidified glycine buffer followed by the pH neutralization with sodium hydroxide. The microplates were coated with anti-rabbit IgG, thereafter the measurements were carried out using two approaches, one with a prior incubation of samples with the anti-h-IGF-I antibody and another without previous incubation (simultaneous addition of IGF-I and biotinylated sample). The best results were obtained using the method without the prior incubation, using the following combination of reagents: microplates were coated with 0.25µg/well of anti-rabbit IgG, the specific antibody at a dilution of 1:250,000 and 0.06ng/well of biotinylated IGF-I. The in house methodology showed sensitivity of 50ng/ml, a correlation between doses of 0.945 when compared to a commercial method. In addition, after 33 assays (quantification of 1114 samples) the proposed methodology presented a good precision, with inter-assay variation coefficients of 12.94% and 20.71% for the high and low controls, respectively. Finally, we concluded that ELISA method for the quantification of total IGF-I using the system biotin-streptavidin-peroxidase amplification in a competitive assay is established and is presented as a useful tool for studies aimed at monitoring the IGF-I concentrations.

Abstract in Portuguese:

RESUMO.- Maioli M.A. & Nogueira G.P. 2017. [Standardization of ELISA for the measurement of Insulin-Like Growth Factor I (IGF-I) in bovine plasm.] Padronização da quantificação do fator de crescimento semelhante a insulina I (IGF-I) em plasma bovino por ELISA. Pesquisa Veterinária Brasileira 37(12):1545-1553. Departamento de Apoio a Produção e Saúde Animal, Faculdade de Medicina Veterinária de Araçatuba, Universidade Estadual Paulista, Unesp-Araçatuba, Rua Clóvis Pestana 793, Araçatuba, SP 16050-680, Brazil. E-mail: maioli_marcos@hotmail.com Esse estudo teve como objetivo a padronização de um ensaio imunoenzimático competitivo (cELISA) in house para a determinação das concentrações plasmáticas do fator de crescimento semelhante a insulina I (IGF-I) total para a espécie bovina, utilizando o sistema de amplificação biotina-estreptavidina peroxidase. O IGF-I foi extraído das proteínas ligadoras do fator de crescimento semelhante a insulina I (IGFBP), utilizando o tampão glicina acidificado seguido de neutralização do pH com hidróxido de sódio. As microplacas foram sensibilizadas com anti IgG de coelho, e as dosagens realizadas utilizando duas abordagens, um método com incubação prévia das amostras com o anticorpo anti-h-IGF-I e outro sem incubação prévia (adição simultânea de IGF-I biotilinado e amostra). Os melhores resultados foram obtidos utilizando o método sem incubação prévia, com a sensibilização da placa com 0,25μg/poço de anti-IgG de coelho, o anticorpo específico na diluição 1:250.000 e 0,06ng/poço de IGF-I biotinilado. O ensaio in house apresentou um limite inferior de detecção de 50ng/mL, uma correlação de 0,945 entre doses quando comparado a uma metodologia comercial. Os coeficientes de variação inter-ensaio de 12,94% (345,8ng/mL) para os controles alto e 20,71% (131,6ng/mL) para o baixo. Dessa forma, conclui-se que a metodologia imunoenzimática para quantificação de IGF-I total utilizando o sistema de amplificação biotina-estreptavidina peroxidase em um ensaio competitivo está estabelecida e apresenta-se como uma ferramenta útil para estudos que visem o monitoramento das concentrações de IGF-I.


#5 - Adrenal glands measurements and ultrasound evaluation in nonhuman primates: squirrel monkey (Saimiri sciureus), owl monkey (Aotus azarae infulatus) and howler monkey (Alouatta guariba clamitans), 34(9):903-910

Abstract in English:

ABSTRACT.- Souza A.C., Lange R.R., Przydzimirski A.C., Castro P.H.G., Pascoli A., Junior J.C.S. & Froes T.R. 2014. [Adrenal glands measurements and ultrasound evaluation in nonhuman primates: squirrel monkey (Saimiri sciureus), owl monkey (Aotus azarae infulatus) and howler monkey (Alouatta guariba clamitans).] Avaliação ultrassonográfica e mensurações das glândulas adrenais em primatas não humanos neotropicais: mico-de-cheiro (Saimiri sciureus), macaco-da-noite (Aotus azarae infulatus) e bugio-ruivo (Alouatta guariba clamitans). Pesquisa Veterinária Brasileira 34(9):903-910. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: froestilde@gmail.com The adrenal glands have endocrine functions related to multiple vital functions and are closely related to the animal’s ability to adapt to stress. The ultrasound is the diagnostic method of choice for evaluation of glands in different species. Considering the scarce literature, one may question whether the adrenal disorders in nonhuman primates are uncommon or underdiagnosed, and a hypothesis exists that this fact is determined by the lack of parameters. The goal is to describe the sonographic features of the adrenal glands for three species of nonhuman primates kept in captivity: squirrel monkey (Saimiri sciureus), owl monkey (Aotus azarae infulatus) and howler monkey (Alouatta guariba clamitans). It is concluded that it is possible to identify the adrenal glands by ultrasound, and the reference standards have been established successfully for the species in question. It is noteworthy that the adaptation of animals in many stressful environments is often accompanied by a hypertrophy of the adrenal glands, so one should take into account that the measurements performed in this study were established in captive animals.

Abstract in Portuguese:

RESUMO.- Souza A.C., Lange R.R., Przydzimirski A.C., Castro P.H.G., Pascoli A., Junior J.C.S. & Froes T.R. 2014. [Adrenal glands measurements and ultrasound evaluation in nonhuman primates: squirrel monkey (Saimiri sciureus), owl monkey (Aotus azarae infulatus) and howler monkey (Alouatta guariba clamitans).] Avaliação ultrassonográfica e mensurações das glândulas adrenais em primatas não humanos neotropicais: mico-de-cheiro (Saimiri sciureus), macaco-da-noite (Aotus azarae infulatus) e bugio-ruivo (Alouatta guariba clamitans). Pesquisa Veterinária Brasileira 34(9):903-910. Departamento de Medicina Veterinária, Universidade Federal do Paraná, Rua dos Funcionários 1540, Curitiba, PR 80035-050, Brazil. E-mail: froestilde@gmail.com As glândulas adrenais possuem funções endócrinas relacionadas a múltiplas funções vitais, estando intimamente relacionadas à capacidade do animal em se adaptar ao estresse. O exame ultrassonográfico é o método diagnóstico de escolha para avaliação das glândulas em diferentes espécies. Considerando a escassa literatura, questiona-se se as doenças adrenais em primatas não humanos são incomuns ou subdiagnosticadas, havendo a hipótese desse fato ser determinado pela falta de parâmetros. Objetivou-se descrever as características ultrassonográficas das glândulas adrenais para três espécies de primatas não humanos mantidas em cativeiro: Saimiri sciureus (mico-de-cheiro), Aotus azarae infulatus (macaco-da-noite) e Alouatta guariba clamitans (bugio-ruivo). Conclui-se que é possível a identificação das glândulas adrenais por meio de exame ultrassonográfico, sendo que os padrões de referência foram estabelecidos com sucesso para as espécies em questão. Ressalta-se que a adequação de animais em ambientes estressantes é frequentemente acompanhada por uma hipertrofia das glândulas adrenais, portanto deve-se levar em consideração que as mensurações realizadas nesse estudo foram estabelecidas em animais de cativeiro.


#6 - echnique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill, 33(2):254-260

Abstract in English:

ABSTRACT.- Dias D.P.M., Teixeira L.G., Bernardi N.S., Gravena K., Albernaz R.M., Valadão C.A.A., Queiroz Neto A. & Lacerda Neto J.C. 2013. [Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill.] Técnica para avaliação da pressão arterial pulmonar de equinos durante o exercício progressivo em esteira rolante. Pesquisa Veterinária Brasileira 33(2):254-260. Departamento de Clínica e Cirurgia Veterinária, Faculdade de Ciências Agrárias e Veterinárias, Universidade Estadual Paulista, Via de Acesso Prof. Paulo Donato Castellane s/n, Jaboticabal, SP 14884-900, Brazil. E-mail: deborah_dias@hotmail.com The aim of this study was to illustrate the surgical implantation of Swan Ganz introducers into the jugular vein, as well as the pulmonary artery cannulation procedure using ten mixed breed (MB) adult horses. We also proposed to demonstrate pulmonary arterial pressure (PAP) values measured through the implanted Swan Ganz during one incremental submaximal exercise test performed on a treadmill. Surgical implantation of the Swan Ganz introducers has demonstrated to be easy and quick to perform. None of the animals showed signs of discomfort following the surgery and ergometric test was carried out as proposed. PAP increased proportionally with exercise intensity, and the major average values were recorded at the higher effort time points. The PAP average values increased (P<0.05) when treadmill speed reached 7.5m/s (39±3mmHg) and 8.5m/s (41±3mmHg), comparing to average values at rest (26±3mmHg). However, the PAP values observed at the maximal effort performed by the MB horses of this trial (41±3mmHg), are under the values described for other breeds at similar effort tests. The technique described in the present study contributes for the standardization of research protocols using arterial pulmonary access via Swan Ganz catheter implantation in horses. The ergometric test was effective to promote PAP changes according to the effort, showing PAP values for MB horses that can guide further investigations.

Abstract in Portuguese:

RESUMO.- Dias D.P.M., Teixeira L.G., Bernardi N.S., Gravena K., Albernaz R.M., Valadão C.A.A., Queiroz Neto A. & Lacerda Neto J.C. 2013. [Technique for pulmonary arterial pressure measurement in horses during the incremental exercise on a treadmill.] Técnica para avaliação da pressão arterial pulmonar de equinos durante o exercício progressivo em esteira rolante. Pesquisa Veterinária Brasileira 33(2):254-260. Departamento de Clínica e Cirurgia Veterinária, Faculdade de Ciências Agrárias e Veterinárias, Universidade Estadual Paulista, Via de Acesso Prof. Paulo Donato Castellane s/n, Jaboticabal, SP 14884-900, Brazil. E-mail: deborah_dias@hotmail.com Objetivou-se ilustrar a técnica cirúrgica de implantação de introdutores para cateter de Swan Ganz na veia jugular, bem como o procedimento de canulação da artéria pulmonar de dez equinos adultos sem raça definida (SRD). Realizando medidas através do cateter de Swan Ganz implantado, objetivou-se ainda demonstrar os valores de pressão arterial pulmonar (PAP) durante um teste de esforço progressivo de intensidade submáxima realizado em esteira rolante. A técnica cirúrgica de implantação de introdutores para o cateter de Swan Ganz empregada, demonstrou-se de fácil e rápida realização. Os animais não apresentaram complicações frente ao introdutor implantado e o teste ergométrico foi realizado conforme proposto. A PAP se elevou ao longo do exercício seguindo o incremento de velocidade, sendo os maiores valores médios observados nos momentos de maior intensidade do esforço. Os valores médios de PAP aumentaram (p<0,05) às velocidades de 7,5m/s (39±3 mmHg) e 8,5m/s (41±3 mmHg), quando comparados aos valores mensurados no repouso (26±3mmHg). Entretanto, os valores de PAP encontrados no máximo de esforço realizado pelos equinos SRD deste ensaio (41±3mmHg), encontram-se abaixo dos valores descritos para outras raças para a mesma intensidade de esforço. A descrição detalhada da técnica ilustrada no presente trabalho, pode contribuir substancialmente na padronização de protocolos experimentais que propõem o acesso arterial pulmonar por meio da implantação de cateter de Swan Ganz em equinos. O teste ergométrico proposto foi eficaz em promover variações de PAP de acordo com o esforço realizado, demonstrando valores para equinos SRD que poderão ser usados como base para futuras avaliações.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV