Resultado da pesquisa (3)

Termo utilizado na pesquisa orthopedics

#1 - Interlocking nail system in comparison with dynamic compression plate in the stabilization of intertrochanteric varus osteotomy in dogs: study in cadavers, 37(12):1474-1478

Abstract in English:

ABSTRACT.- Carneiro L.Z., Mistieri M.L.A., Cauduro C.R., Rosa A.F. & Pascon J.P.E. 2017. [Interlocking nail system in comparison with dynamic compression plate in the stabilization of intertrochanteric varus osteotomy in dogs: study in cadavers.] Haste intramedular bloqueada em comparação com placa de compressão dinâmica na estabilização de osteotomia intertrocantérica varizante em cães: estudo ex vivo. Pesquisa Veterinária Brasileira 37(12):1474-1478. Hospital Universitário Veterinário, Universidade Federal do Pampa, BR-472 Km 592, Uruguaiana, RS 97508-000, Brazil. E-mail: malimistieri@gmail.com Considering the advantages of the interlocking intramedullary nail (IN) in relation to bone plates in the femoral stabilization, this study aimed to evaluate the feasibility and effectiveness of IN application post intertrochanteric varus osteotomy (IVO). For this purpose, 10 canines cadavers were used. On the left femurs, the fixation was obtained with IN (IN group) and rights fixed with dynamic compression plates and screws (plate group). Was compared the angles of Norberg and inclination of the head and femoral neck (IHF) before (T0) and after (T1) IVO. The results of time spent for placement of implants and biomechanical resistance to compression and torsion were also confronted between groups. There was an increase of the Norberg angle between T0 (106.84±5.55o) and T1 (111.22o±3.89), only in IN group (p<0.05). However, reduction of IHF angle after IVO (T1) was observed in both, the plate group (T0=127.6±4.70o e T1=110.06±10.61o, p<0.05) and IN group (T0=126.43±5.87o e T1=116.87± 8.62 o, p<0.05). The placement times of the implants did not differ statistically and only the compression biomechanical test revealed differences between groups, with greater resistance (P=0.033) of the plate group (863.3±74.46N/mm) compared to IN group (586.7±44.10N/mm). Thus, stabilization through IN was feasible and effective. Although the compression biomechanical results has demonstrated a higher fragility of IN in relation to the compression plate, their values are above the forces, reported in literature, acting in normal dog gait.

Abstract in Portuguese:

RESUMO.- Carneiro L.Z., Mistieri M.L.A., Cauduro C.R., Rosa A.F. & Pascon J.P.E. 2017. [Interlocking nail system in comparison with dynamic compression plate in the stabilization of intertrochanteric varus osteotomy in dogs: study in cadavers.] Haste intramedular bloqueada em comparação com placa de compressão dinâmica na estabilização de osteotomia intertrocantérica varizante em cães: estudo ex vivo. Pesquisa Veterinária Brasileira 37(12):1474-1478. Hospital Universitário Veterinário, Universidade Federal do Pampa, BR-472 Km 592, Uruguaiana, RS 97508-000, Brazil. E-mail: malimistieri@gmail.com Tendo em vista as vantagens das hastes intramedulares bloqueadas (HIB) em relação às placas ósseas na estabilização femoral, o presente estudo objetivou avaliar a exequibilidade e eficácia da aplicação da HIB pós osteotomia intertrocantérica varizante (OIV). Submeteu-se 10 cadáveres caninos à OIV. Nos antímeros esquerdos obteve-se a estabilização por meio de HIB (grupo HIB) e, nos direitos, com placas de compressão dinâmica (grupo placa). Foram comparados os ângulos de Norberg e de inclinação da cabeça e colo femoral (ICF) antes (T0) e após (T1) a OIV. O tempo dispendido para a colocação dos implantes e resultados de resistência biomecânica à compressão e torção também foram confrontados entre os grupos. Houve aumento do ângulo de Norberg entre T0 (106,84±5,55o) e T1 (111,22o±3,89), apenas no grupo HIB (p<0,05). No entanto, redução do ângulo de ICF após OIV (T1) foi observada tanto no grupo placa (T0=127,6±4,70o e T1=110,06±10,61o, p<0,05) quanto no grupo HIB (T0=126,43±5,87o e T1=116,87±8,62o, p<0,05). Os tempos de colocação dos implantes não diferiram estatisticamente e apenas o teste biomecânico de compressão revelou diferença entre os grupos, com maior resistência (P=0,033) do grupo placa (863,3±74,46N/mm) em relação ao grupo HIB (586,7±44,10N/mm). Deste modo, a estabilização por meio de HIB foi factível e eficaz. Embora o resultado biomecânico de compressão tenha demonstrado maior fragilidade da HIB em relação à placa de compressão, seus valores estão acima das forças atuantes, reportadas na literatura, na deambulação normal de cão.


#2 - Conservative and surgical treatment in 22 ruminants with limb fractures, 34(11):1045-1050

Abstract in English:

ABSTRACT.- Câmara A.C.L., Calado E.B., Antunes J.M.A.P., Oliveira C.M.M., Afonso J.A.B. & Costa N.A. 2014. [Conservative and surgical treatment in 22 ruminants with limb fractures.] Tratamento conservativo e cirúrgico em 22 ruminantes com fraturas em membros. Pesquisa Veterinária Brasileira 34(11):1045-1050. Hospital Veterinário, Universidade Federal Rural do Semi-Árido, BR-110 Km 47, Presidente Costa e Silva, Mossoró, RN 59625-900, Brazil. E-mail: aclcamara@yahoo.com.br The aim of the present study was to report the main locations of limb fractures in 22 ruminants and to determine the efficiency of the treatment choices. Eight goats, eight sheep and six cattle were included. In cases of distal fractures, the conservative treatment with immobilization was the method of choice. In cases of proximal, exposed metatarsal or metacarpal fractures, the ruminants were treated surgically. The higher frequency of fractures involved the metacarpal or metatarsal (54.5%) followed by fractures of the tibia (22.7%), femur (9%) and isolated cases of medial phalanx, humerus, radius and ulna fractures (4.5% each). Total recovery rate reached 95.4%. Immobilization with plaster associated with Thomas splint, or just with wooden splints in young animals, was efficient in reducing fractures of metacarpal, metatarsal, tibia, humerus, and radio in the treated ruminants. In the case of medial phalanx fracture, immobilization using only plaster was sufficient to provide adequate bone repair. The internal or external skeletal fixation should be considered an option in the treatment of metacarpal, metatarsal, tibial and femoral fractures in ruminants, especially in low body weight animals.

Abstract in Portuguese:

RESUMO.- Câmara A.C.L., Calado E.B., Antunes J.M.A.P., Oliveira C.M.M., Afonso J.A.B. & Costa N.A. 2014. [Conservative and surgical treatment in 22 ruminants with limb fractures.] Tratamento conservativo e cirúrgico em 22 ruminantes com fraturas em membros. Pesquisa Veterinária Brasileira 34(11):1045-1050. Hospital Veterinário, Universidade Federal Rural do Semi-Árido, BR-110 Km 47, Presidente Costa e Silva, Mossoró, RN 59625-900, Brazil. E-mail: aclcamara@yahoo.com.br O objetivo do presente trabalho foi relatar os principais locais de fraturas em membros de 22 ruminantes e determinar a eficiência dos tratamentos utilizados. Foram incluídos no estudo oito caprinos, oito ovinos e seis bovinos Em casos de fraturas distais, o tratamento conservativo com imobilização foi o método de eleição. Em casos de fraturas proximais e fraturas expostas de metatarso ou metacarpo, os ruminantes foram tratados cirurgicamente. Observou-se maior frequência de fraturas envolvendo o metacarpo ou metatarso (54,5%), seguido por fraturas de tíbia (22,7%), fêmur (9%) e casos isolados de fraturas de falange medial, úmero, rádio e ulna (4,5% cada). O índice de recuperação total alcançou 95,4%. A imobilização com gesso associada à tala de Thomas, ou apenas com talas de madeira em animais jovens, foi eficiente na redução de fraturas de metacarpo, metatarso, tíbia, úmero e rádio nos ruminantes tratados. Enquanto no caso de fratura de falange medial, a imobilização com uso apenas de gesso foi suficiente para proporcionar reparação óssea adequada. A fixação esquelética externa ou interna deve ser considerada uma opção no tratamento de fraturas metacárpicas, metatársicas, tibiais e femorais em ruminantes, principalmente quando o animal for de baixo peso corporal.


#3 - Uso de fixador esquelético externo Tipo II para osteossíntese de tibiotarso em galinhas da raça Plymouth Rock Branca: modelo experimental para uso em aves selvagens, 199-204

Abstract in English:

ABSTRACT.- De Conti J.B., Schossler J.E.W., Alievi M.M., Bonfada A.T., Novosad D., Silva D. & Pachaly J.R. 2007. [Use of Type II external skeletal fixator for tibiotarsus osteosynthesis in White Plymouth Rock chickens: An experimental model for using in wild birds.] Uso de fixador esquelético externo Tipo II para osteossíntese de tibiotarso em galinhas da raça Plymouth Rock Branca: modelo experimental para uso em aves selvagens. Pesquisa Veterinária Brasi-leira 27(5):199-204. Curso de Medicina Veterinária, Universidade Estadual de Maringá, Estrada da Paca s/n, Zona Rural, Umuarama, PR 87502-000, Brazil. E-mail: julianodeconti@yahoo.com.br The efficiency of the Type II external skeletal fixator for the treatment of tibiotarsus fracture in eight adult White Plymouth Rock chickens was evaluated. The individuals were pre-medicated with morphine sulfate and anesthetized with halothane, and submitted to a diaphysary osteotomy in the left tibiotarsus, performed with an oscillatory saw. Four Kirschner wires were inserted through the bone cortices, being two proximally and two distally to the fracture. After the fracture reduction the ends of both proximal and distal wires were twisted in distal or proximal direction, respectively, being the wires connected by two bars of autopolymerizing acrylic resin, in the external lateral and medial faces of the limb. The return to full capability to use the member was observed in 20.00±7.09 days, and the bone healing occurred in 35.12±8.72 days. The results of this study showed that open reduction and use of Type II external skeletal fixator is an effective method for the treatment of tibiotarsus fractures in White Plymouth Rock chickens.

Abstract in Portuguese:

ABSTRACT.- De Conti J.B., Schossler J.E.W., Alievi M.M., Bonfada A.T., Novosad D., Silva D. & Pachaly J.R. 2007. [Use of Type II external skeletal fixator for tibiotarsus osteosynthesis in White Plymouth Rock chickens: An experimental model for using in wild birds.] Uso de fixador esquelético externo Tipo II para osteossíntese de tibiotarso em galinhas da raça Plymouth Rock Branca: modelo experimental para uso em aves selvagens. Pesquisa Veterinária Brasi-leira 27(5):199-204. Curso de Medicina Veterinária, Universidade Estadual de Maringá, Estrada da Paca s/n, Zona Rural, Umuarama, PR 87502-000, Brazil. E-mail: julianodeconti@yahoo.com.br The efficiency of the Type II external skeletal fixator for the treatment of tibiotarsus fracture in eight adult White Plymouth Rock chickens was evaluated. The individuals were pre-medicated with morphine sulfate and anesthetized with halothane, and submitted to a diaphysary osteotomy in the left tibiotarsus, performed with an oscillatory saw. Four Kirschner wires were inserted through the bone cortices, being two proximally and two distally to the fracture. After the fracture reduction the ends of both proximal and distal wires were twisted in distal or proximal direction, respectively, being the wires connected by two bars of autopolymerizing acrylic resin, in the external lateral and medial faces of the limb. The return to full capability to use the member was observed in 20.00±7.09 days, and the bone healing occurred in 35.12±8.72 days. The results of this study showed that open reduction and use of Type II external skeletal fixator is an effective method for the treatment of tibiotarsus fractures in White Plymouth Rock chickens.


Colégio Brasileiro de Patologia Animal SciELO Brasil CAPES CNPQ UNB UFRRJ CFMV